![Garland XPE12 Service Manual Download Page 24](http://html1.mh-extra.com/html/garland/xpe12/xpe12_service-manual_564395024.webp)
24
Document: GAR_SM_4601777 (4/16)
General Information
Section 1
Gas Input Specification
Gas Grills, 1, 2 & 3 Platen North America - all CSA models.
GAS
MAX INPUT
(NET) PER
BURNER
(BTU/H)
TOTAL INPUT
RATING
(BTU/H)
INJECTOR
SIZE
SUPPLY PRESSURE
(IN W.C.)
BURNER MANIFOLD
PRESSURE
(IN W.C.)
1
Platen
NATURAL GAS
10,000
20,000
1.5mm
7.0” WC
4.0” WC
PROPANE
20,000
1.2mm
11.0” WC
2
Platen
NATURAL GAS
40,000
1.5mm
7.0” WC
PROPANE
40,000
1.2mm
11.0” WC
3
Platen
NATURAL GAS
60,000
1.5mm
7.0” WC
PROPANE
60,000
1.2mm
11.0” WC
Input Specifi cation - All CE Models.
GAS
GROUP
MAX INPUT (NET)
PER BURNER (kW)
TOTAL INPUT RATING (kW)
INJECTOR
SIZE (mm)
BURNER
PRESSURE (mbar)
FAN SPEED
SETTING (RPM)
G20
2.93
5.86kW - (For XPE12 series)
11.72kW - (For XPE24 series)
17.58kW - (For XPE36 series)
1.5mm
10mbar
(4.0” WC)
10,000
G25
2.93
5.86kW - (For XPE12 series)
11.72kW - (For XPE24 series)
17.58kW - (For XPE36 series)
1.5mm
13.7mbar
(5.5” WC)
G31
2.93
5.86kW - (For XPE12 series)
11.72kW - (For XPE24 series)
17.58kW - (For XPE36 series)
1.2mm
10mbar
(4.0” WC)
For G31 propane gas, the unit has been set at the factory for a 37mbar supply pressure. A factory authorized service
technician must adjust the unit if a 30mbar supply pressure is used.
COUNTRY
GAS CATEGORY
GAS TYPE
SUPPLY PRESSURE (mbar)
AT, CH, CY, CZ, DK, EE, ES, FI, FR, GB, GR, HR, IE, IT, LT, LU,
LV, NL, NO, PT, RO, SE, SI, SK, TR
I2H
G20
20
HU
I2H
G20
25
DE, LU, PL, RO
I2E
G20
20
BE
I2E(R)
G20
20
FR
I2E(r)
G20/G25
20/25
FR, NL
I2L
G25
25
RO
I2L
G25
20
FI, HU,NL, RO
I3P
G31
30
BE, CH, CZ, ES, FR, GB, GR, HU, IE, IT, LT, NL, PL, PT, SI, SK,
HR
I3P
G31
37
AT, BE, CH, CZ, DE, ES, FR, GB, GR, HU, NL, SK
I3P
G31
50
NOTE: For installations up to 2000ft. units being installed at higher elevation must be configured accordingly at the factory