Part # 1844066 Rev 01 (02/13/2008)
Page 8
OPERATING INSTRUCTIONS Continued
Setting Air Temperature (default mode)
°F
°C
1. Press the Select Key until “Air” appears on the display.
Notice the LED is illuminated and will remain
illuminated until the set mode is exited. You will exit set
mode automatically when no key has been pressed for 5
seconds. The last value entered will be stored in memory.
2. Press the or key to increase or decrease the
displayed air temperature. The factory default is 150°F or
66°C.
°F
°C
NOTE: The temperature programmed here will become the
default setting. This setting will be restored even after the
power has been turned off.
Setting Humidity (default mode):
°F
°C
1. Press the Select Key until “HU” appears on the display.
Notice the LED is illuminated and will remain
illuminated until the set mode is exited. You will exit set
mode automatically when no key has been pressed for 5
seconds. The last value entered will be stored in memory.
°F
°C
2. Press the or key to increase or decrease the
displayed humidity setting. To activate the humidity the
setting must be greater than 10. To operate in dry mode
set the display to 10. The factory default is 50.
NOTE: The temperature programmed here will become the
default setting. This setting will be restored even after the
power has been turned off.