![Garland Mealstream Service Manual Download Page 51](http://html1.mh-extra.com/html/garland/mealstream/mealstream_service-manual_3728510051.webp)
Mealstream Ovens Pt. No. 32Z3403 Issue 15
Page 51
APPENDIX 3:
TEMPERATURE SENSOR RESISTANCE DATA
Temp °F
Temp °C
Min. Rate
k
Ω
Standard
Rate k
Ω
Max. Rate
k
Ω
212
100
11.490
13.060
14.810
302
150
2.803
3.161
3.434
392
200
0.950
1.000
1.050
482
250
0.3572
0.3865
0.4171
R(200)°C = 1 k
Ω
±
5%
Temperature Sensor Resistance
Note:
These resistances will only be apparent in a stable cavity temperature as the
sensor has a slow response time.