Part # 4515576 Rev 1 (01/21/10)

Page 1

Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent 

using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been 

improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation 

instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, 

or which has been modified or repaired using unauthorized parts or by unauthorized service agents. 

For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com. 

The information contained herein, (including design and parts specifications), may be superseded and is subject 

to change without notice.

GARLAND COMMERCIAL INDUSTRIES

185 East South Street

Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903

GARLAND COMMERCIAL RANGES, LTD.

1177 Kamato Road, Mississauga, Ontario L4W 1X4

CANADA
Phone: 905-624-0260
Fax: 905-624-5669

Part # 4515576 Rev 1 (01/21/10)

© 2004 Garland Commercial Industries, Inc.

FOR YOUR SAFETY:

DO NOT STORE OR USE GASOLINE 

OR OTHER FLAMMABLE VAPORS OR 

LIQUIDS IN THE VICINITY OF 

THIS OR ANY OTHER

APPLIANCE

WARNING:

IMPROPER INSTALLATION, ADJUSTMENT, 
ALTERATION, SERVICE OR MAINTENANCE 
CAN CAUSE PROPERTY DAMAGE, INJURY, 

OR DEATH. READ THE INSTALLATION, 

OPERATING AND MAINTENANCE 

INSTRUCTIONS THOROUGHLY 

BEFORE INSTALLING OR 

SERVICING THIS EQUIPMENT

PLEASE READ ALL SECTIONS OF THIS MANUAL 

AND RETAIN FOR FUTURE REFERENCE.

THIS PRODUCT HAS BEEN CERTIFIED AS 

COMMERCIAL COOKING EQUIPMENT AND 
MUST BE INSTALLED BY PROFESSIONAL 
PERSONNEL AS SPECIFIED. 

IN THE COMMONWEALTH OF MASSACHUSETTS 

THIS PRODUCT MUST BE INSTALLED BY A 

LICENSED PLUMBER OR GAS FITTER. 

For Your Safety:
Post in a prominent location, instructions to be 
followed in the event the user smells gas. This 
information shall be obtained by consulting 
your local gas supplier.

INSTALLATION AND 

OPERATION MANUAL

MASTER SERIES

INFRA-RED & CERAMIC 

BROILER

Summary of Contents for M60XR

Page 1: ...Fax 570 636 3903 GARLAND COMMERCIAL RANGES LTD 1177 Kamato Road Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Part 4515576 Rev 1 01 21 10 2004 Garland Commercial Industries In...

Page 2: ...could expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of California to cause cancer Operation of this...

Page 3: ...Notes 6 Appliances Equipped With Casters 7 Appliances Equipped With Legs 7 Testing Adjustment 7 FDO Heavy Duty Oven control 7 OPERATION 9 Broiler Section 9 Cast Iron Burner With Ceramic Tile M60X 9 I...

Page 4: ...r With Ceramic Tile 80 000 48 Infra Red 70 000 56 Oven 35 000 50 Model Designations Model Number Broiler Burner Base M60XR Cast Iron Burner With Ceramic Tile Standard Oven M60XRC Cast Iron Burner With...

Page 5: ...ange products are not approved or authorized for home or residential use but are intended for commercial applications only Garland U S Range will not provide service warranty maintenance or support of...

Page 6: ...gas supply to the kitchen to enable it to be isolated in an emergency Wherever practical this shall be located either outside the kitchen or near to an exit in a readily accessible position Where it i...

Page 7: ...y be necessary to remove or at least raise and securely prop griddles hot top and or top grates All parts removed including fasteners should be stored safely for re installation INSTALLATION Continued...

Page 8: ...n pyrometer To check calibration proceed as follows 1 Place the thermocouple of the test instrument or reliable mercury thermometer in the center of the oven 2 Turn the oven temperature control knob t...

Page 9: ...ed in These special burners operate in a manner similar to that of a conventional gas burner except that the radiation surfaces consist of a series of ceramic blocks each containing numerous small gas...

Page 10: ...vens RC Lighting Same as standard oven Start Up 1 Activate the power switch to COOK position 2 Turn oven valve ON 3 Turn thermostat to desired setting Cool Down 1 Turn thermostat and oven valve OFF 2...

Page 11: ...on Porterhouse 1 25 2 1 2 4 5 1 2 T bone Club Rib 1 1 2 38 2 1 2 4 5 1 2 Sirloin 2 51 3 1 2 5 1 2 6 1 2 Strip Sirloin 3 4 19 2 1 2 3 1 2 5 Ground Steak 1 2 13 1 1 2 2 2 1 2 Lamb Loin Rib Chops 1 25 3...

Page 12: ...an sponge dipped in a sanitizing solution and wipe dry with soft clean cloth before it can dry Use a paste of water and a mild scouring powder if you have to but never rub against the grain All stainl...

Page 13: ...ully place the control knobs back into position CARE CLEANING Continued Instructions For Removal Of Grid Rack Grid Rack Frame Remove the broiler grid racks as follows 1 Bring the grid rack down to the...

Page 14: ...Part 4515576 Rev 1 01 21 10 Page 14 WIRING DIAGRAM...

Page 15: ...Part 4515576 Rev 1 01 21 10 Page 15...

Page 16: ......

Page 17: ......

Page 18: ...Part 4515576 Rev 1 01 21 10 Page 15 SCH MA DE C BLAGE...

Page 19: ...Avant de nettoyer la tr mie remettre en place le tiroir graisse afi n d y recueillir toutes des particules ou gouttes cons cutives au nettoyage Un d fl ecteur graisse interne suppl mentaire doit tre...

Page 20: ...rs l avant pour la lib rer des guides du cadre de cr maill re M110XM Le fi ltre de l appareil M110XM doit tre retir et nettoy tous les jours ou tous les deux jours en fonction de l utilisation Le fi l...

Page 21: ...d form s Ne pas utiliser un plat profond pour les g teaux peu pais les petits g teaux etc tant donn que la circulation de l air au dessus de ces aliments est essentielle pour un brunissage r gulier P...

Page 22: ...rer la grille de la r tissoire Il est important de souligner une fois de plus que les indications de temps indiqu es plus haut sont donn es titre d indication La technique de l utilisateur et son exp...

Page 23: ...age Comme pour le four standard D marrage 1 Mettre l interrupteur d alimentation en position COOK Cuisson 2 Tourner le robinet du four en position ON 3 Tourner le thermostat sur le r glage d sir Refro...

Page 24: ...halo dispara t et la c ramique devient rouge Arr t 1 Tourner tous les robinets en position OFF 2 Couper l alimentation lectrique l interrupteur principal 0 3 Si l appareil doit tre teint pour une p ri...

Page 25: ...nt n cessaire et on ne devra pas essayer de le faire sauf si les r sultats de cuisson d montrent sans aucun doute que les commandes ne maintiennent pas les temp ratures sur lesquelles sont r gl es les...

Page 26: ...nt tre test s pour d tecter les fuites ventuelles Utiliser des d tecteurs de fuites approuv s de l eau savonneuse ou des produits quivalents appliqu s sur et autour des raccords et connexions de tuyau...

Page 27: ...lors de toute intervention d entretien ou de nettoyage Un raccord union ou tout autre moyen de d connexion doit tre install entre le robinet de gaz et l appareil Un robinet commande manuelle doit tre...

Page 28: ...sion d alimentation pour lesquels l quipement a t r gl en usine sont indiqu s sur la plaque signal tique et sur l emballage Ce type d alimentation en gaz doit tre utilis 5 Ne pas retirer les tiquettes...

Page 29: ...uile C ramique 80 000 48 Infrarouge 70 000 56 Four 35 000 50 D signations Des Mod les Num ro de mod le Br leur de r tissoire Base M60XR Br leur de Fonte Avec la Tuile C ramique Four standard M60XRC Br...

Page 30: ...pareils quip s De Roulettes 7 Appareils quip es De Pieds 7 Essais Et R glages 7 Commande De Four Robuste FDO 8 FONCTIONNEMENT 9 Section R tissoire 9 Br leur de Fonte Avec la Tuile C ramique M60X 9 Br...

Page 31: ...si res de laine de verre fibres c ramiques L inhalation de ces particules de laine de verre ou de fibres c ramiques est reconnue par l tat de Californie comme causant le cancer L utilisation de ce pro...

Page 32: ...AND COMMERCIAL RANGES LTD 1177 Kamato Road Mississauga Ontario L4W 1X4 CANADA T l phone 905 624 0260 T l copieur 905 624 5669 Pi ce n 4515576 Rev 1 01 21 10 2004 Garland Commercial Industries Inc POUR...