Part # 1382669 (07/05)
Page 5
DIMENSIONS AND SPECIFICATIONS, MODEL IR-280L SERIES
4-1/2"
[114mm]
1-3/4"
[44mm]
3-1/2"
[89mm]
1-3/8"
[35mm]
OPTIONAL
REAR
GAS
INLET
3-1/4"
[83mm]
OPTIONAL
REAR
GAS
INLET
1/2"N.P.T.
[83mm]
TOP
GAS
INLET
18"
[457mm]
1-3/4"
[45mm]
9"
[229mm]
34"
[864mm]
15"
[381mm]
15"
[381mm]
30"
[762mm]
36"
[914mm]
Gas input ratings shown for installations up to
2000 ft., (610m), above sea level.
Please specify altitudes over 2000 ft.
For use on noncombustible floors
Commercial cooking equipment requires an
adequate ventilation system. For additional
information, refer to the National Fire Protection
Association's standard NFPA96.
This product is not approved for residential use.
Model
Width
Use With H280
Series Model
Shipping Wt.
Lbs./Kgs.
Entry Clearances: In (mm)
Crated
Uncrated
IR36-280L
36" (914mm)
H286
200/91
29" (737mm)
21" (533mm)
IR48-280L
48"(1219mm)
(36" b 12"/305mm flue riser w/shelf)
H288
230/105
29" (737mm)
21" (533mm)
IR60-280L
60" (1524mm)
(36" b 24"/610mm flue riser w/shelf)
H284 & H287
260/118
29" (737mm)
21" (533mm)
IR72-280L
72" (1829mm)
(36" b 36"/914mm flue riser w/shelf)
H289
280/127
29" (737mm)
21" (533mm)
Note Salamander Broiler on Left Side. Right Side Optional
Operating Pressure
Installation Clearances
Total Input
Orifice
Natural
Propane
Sides
Rear
40,000 BTU/HR (11.7Kw)
NAT
PRO
6"WC (15mbar)
11"WC (28mbar)
6"(152mm)
6"(152mm)
#48F
#55F
Summary of Contents for IR36-280L