![Garland INT40G2-44 User Manual Download Page 18](http://html1.mh-extra.com/html/garland/int40g2-44/int40g2-44_user-manual_3643058018.webp)
Packet Broker
EdgeLens Inline Security Packet Broker | INT40G2XR44 | 1.19.5
2. Enter the No. Of Lost HB Packets. Default is 10.
This is the number of heartbeats that must be lost on the inline appliance ports before any
tap will switch to bypass.
3. Enter the Heartbeats per Second. Default is 10.
This is the number of heartbeats per second applied to the inline appliance ports for all taps.
4. Select Save to save updates.
5. Select Cancel to return the Bypass Taps panel.
3.1.3 Taps Settings
The following configuration options may be displayed, modified, enabled, or disabled.
Tap Mode
Reverse Bypass
Fail Mode
Revertive
LFP
Coupled
1. Edit the Tap Settings, by placing the cursor on any tap and double-press the left mouse button.
The Tap panel will be displayed.
2. Select Edit Tap Settings.
The Configure Inline Appliance panel will be displayed.
3. Select the Tap Mode.
Active
Allows the tap to automatically switch from inline to bypass if an issue occurs
with the primary inline appliance port(s) and secondary inline appliance port(s),
loss of link or heartbeats. The default switching action from inline to bypass
is defined by the system as, from the primary inline appliance, to the secondary
inline appliance, to bypass. The default switching action from bypass to inline
is defined by the system as, from bypass, to the secondary inline appliance.
Switching from the secondary inline appliance to the primary inline appliance
may be accomplished via two methods. Select the Switch to Primary option
or enable Revertive. If revertive is enabled, then the system will switch from
bypass to the primary inline appliance if it is recovered first.
Fig
ure 2 Primary-Secondary Tap (Primary Inline)
Fig
ure 3 Primary-Secondary Tap (Secondary Inline)