background image

Part #4520414 (01/28/08)

Page 7

OPERATION AND MAINTENANCE

Top and bottom heating units are each operated by a three 

heat heavy duty reversible switch . An oven thermostat with 

pilot light is also provided . The thermostat maintains the 

temperature and the switches determine the source of the 

heat .

1  Turn the top heating unit to HIGH . 

2  Turn the bottom heating unit to HIGH . 

 .  Set the oven thermostat to the desired temperature . The 

pilot light will now come ON . 

4 .  When the desired temperature is reached, the pilot light 

will go OFF . At this time the top heating unit switch may 

be turned OFF or set as desired . 

5  The bottom heating unit switch may be left at HIGH or 

adjusted as desired . 

Thermostat Calibration

All electric ovens are equipped with snap action thermostats . 

Field calibration is seldom necessary and should not be 

resorted to unless experience with cooking results definitely 

provides that the control is not maintaining the temperature 

to which the dial is set . To check the oven temperature when 

calibrating, use only a reliable mercury thermometer or 

preferably an oven pyrometer . 

1 .  Place the thermocouple of the test instrument or reliable 

mercury thermometer in the center of the oven . 

2 .  Turn oven temperature control dial to 400°F (204°C) . In 

order to allow the oven temperature to stabilize, the oven 

control must be allowed to cycle twice before taking a 

test reading

 .  Check temperature reading control just as it cycles ‘OFF” 

as indicated by the cycling pilot . If the temperature doe 

not read within 15°F (8°C) of the dial setting, recalibrate 

as follows

4 .  Carefully remove the thermostat dial, not disturbing the 

dial setting .

5 .  Hold the dial shaft steady and with a screwdriver, turn the 

calibration screw, located inside the dial shaft clockwise 

to decrease and counter-clock wise to increase the 

temperature . I .E . 1/4 turn = 5°F (19 .5°C) .

6 .  Replace the thermostat dial and repeat steps 1 through  

to verify that the correct adjustment has been made . 

Cleaning of Core Plates

1 .  Set the thermostat dial to 550°F (288°C) at the end of the 

cooking day and allow to cycle for one hour . 

2 .  When the oven has cooled the residue will have 

carbonized and can be removed by sweeping with a stiff 

wire brush .

 .  Stubborn residue can be loosened with a scraper . 

Summary of Contents for E2001

Page 1: ...Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Enodis UK LTD Swallowfield Way Hayes Middlesex UB 1DQ ENGLAND Telephone 081 561 04 Fax 081 848 0041 Part 4520414 01 28 08 2005 Garland Commercial Industries Inc FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMEN...

Page 2: ...ate of california to cause cancer and or birth defects or other reproductive harm Installation and servicing of this product could expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of California to cause cancer ...

Page 3: ...Model Description 4 Loading Charts 4 INTRODUCTION 5 Uncrating 5 Rating Plate 5 INSTALLATION 5 Clearances 5 Assembly Instructions 5 Steam Injection Optional Extra 6 Electrical Connections 6 Break In Procedure 6 OPERATION AND MAINTENANCE 7 Thermostat Calibration 7 Cleaning of Core Plates 7 ...

Page 4: ...tion Oven E2115 70 1778mm Two Bake and One Roast Combination Oven E2155 74 1879mm One Bake and Two Roast Combination Oven Loading Charts LOADING CHART Model Total Kw Loading Nominal Amperes Per Phase 3 Phase Single Phase 240V 208V 240V 280V X Y Z X Y Z 240V 208V E2001 6 2 11 15 23 12 5 17 3 26 26 30 E2011 12 4 32 26 32 37 30 37 52 60 E2111 18 6 45 45 45 51 5 51 5 51 5 77 5 90 E2005 6 2 11 15 23 12...

Page 5: ...racteristics agree INSTALLATION Clearances The 2000 E series ovens must be installed with a minimum of zero 0 clearance to the sides and back to walls of combustible material Assembly Instructions 1 Open the bottom section of the crate and the leg crate Proceed with oven assembly as follows a Fasten lefts to base using 1 4 hex head bolts locking washers and nuts provided b Ensure the insulation is...

Page 6: ...ued Electrical Connections The installation and connection should comply with current codes In Canada The Canadian Electrical Code Part 1 and or local codes In the U S A The National Electrical Code ASNA NFPA current edition Before attempting the electrical connection the rating plate should be checked to ensure that the unit s electrical characteristics and the supply characteristics agree The un...

Page 7: ...ly a reliable mercury thermometer or preferably an oven pyrometer 1 Place the thermocouple of the test instrument or reliable mercury thermometer in the center of the oven 2 Turn oven temperature control dial to 400 F 204 C In order to allow the oven temperature to stabilize the oven control must be allowed to cycle twice before taking a test reading 3 Check temperature reading control just as it ...

Page 8: ......