DO NOT under any circumstances; connect the vent stack 

of the oven directly to the flue pipe or a vent system . If this 

is done, it seriously decreases the efficiency and will cause 

uneven heating of the section . If an outside flue connection 

must be made, a suitable hood placed 12” (05mm) above 

the oven flue must be provided to prevent direct suction of 

the air through the oven sections . 

Steam Injection (Optional Extra)

Steam is often used for baking of hard rolls, French bread, 

Vienna bread and other hard crust breads . The steam 

provided inside the oven is a cloud of atmospheric steam or 

water vapor . 

One quarter broiler h .p . for each bake deck is required at 

the steam inlet of the deck . It is important that the steam 

provided to the oven is lower pressure ( lbs . To 5 lbs per 

square inch), (2100 kg/m² to 500 kg/m²) and condensate 

must be drained from the steam line before it enters the 

oven . 

The steam will be sufficiently saturated at this pressure to 

provide the vapor cloud effect that is needed to cover the 

top of the product . 

When steam is required in the deck, it is recommended that 

the steam valve at the deck is only open a half-turn for  

to 5 seconds . The time will be determined by the operator . 

Allowing too much steam to enter the oven will produce a 

soggy product . 

INSTALLATION Continued

Electrical Connections

The installation and connection should comply with current 

codes . In Canada - The Canadian Electrical Code Part 1 and/or 

local codes . In the U .S .A . - The National Electrical Code ASNA/

NFPA -  current edition .

Before attempting the electrical connection, the rating 

plate should be checked to ensure that the unit’s electrical 

characteristics and the supply characteristics agree .

The unit has been wired as specified on the factory order 

and the rating plate is stamped with the information . If it is 

necessary to change the phase, refer to the wiring diagram 

attached to the main terminal block, or refer to the rating 

plate . 

Electrical connection may be made though the knockout at 

the rear of bottom of the unit to the terminal block located 

directly behind the switch panel on the main bottom . Hinge 

switch panel open .

For the supply connection use suitable wire for 60° C .

Break-In Procedure

It is strongly recommended that the 2000 Series ovens 

supplied with core plates be put through a break-in period 

to eliminate possible warpage of the core plates caused by 

moisture absorption .

This action need only be carried out once providing the 

ovens are used daily, however, if the ovens are left idle for an 

extended period of time allowing the core plates to absorb 

moisture, the following procedure must be again carried out . 

Turn the top and bottom heat selector switched to HI, set the 

thermostat to 00°F (149°C) maximum and allow the oven to 

operate (without any product in the oven), for approximately 

8 hours . 

Summary of Contents for E2001

Page 1: ...Mississauga Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Enodis UK LTD Swallowfield Way Hayes Middlesex UB 1DQ ENGLAND Telephone 081 561 04 Fax 081 848 0041 Part 4520414 01 28 08 2005 Garland Commercial Industries Inc FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMEN...

Page 2: ...ate of california to cause cancer and or birth defects or other reproductive harm Installation and servicing of this product could expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of California to cause cancer ...

Page 3: ...Model Description 4 Loading Charts 4 INTRODUCTION 5 Uncrating 5 Rating Plate 5 INSTALLATION 5 Clearances 5 Assembly Instructions 5 Steam Injection Optional Extra 6 Electrical Connections 6 Break In Procedure 6 OPERATION AND MAINTENANCE 7 Thermostat Calibration 7 Cleaning of Core Plates 7 ...

Page 4: ...tion Oven E2115 70 1778mm Two Bake and One Roast Combination Oven E2155 74 1879mm One Bake and Two Roast Combination Oven Loading Charts LOADING CHART Model Total Kw Loading Nominal Amperes Per Phase 3 Phase Single Phase 240V 208V 240V 280V X Y Z X Y Z 240V 208V E2001 6 2 11 15 23 12 5 17 3 26 26 30 E2011 12 4 32 26 32 37 30 37 52 60 E2111 18 6 45 45 45 51 5 51 5 51 5 77 5 90 E2005 6 2 11 15 23 12...

Page 5: ...racteristics agree INSTALLATION Clearances The 2000 E series ovens must be installed with a minimum of zero 0 clearance to the sides and back to walls of combustible material Assembly Instructions 1 Open the bottom section of the crate and the leg crate Proceed with oven assembly as follows a Fasten lefts to base using 1 4 hex head bolts locking washers and nuts provided b Ensure the insulation is...

Page 6: ...ued Electrical Connections The installation and connection should comply with current codes In Canada The Canadian Electrical Code Part 1 and or local codes In the U S A The National Electrical Code ASNA NFPA current edition Before attempting the electrical connection the rating plate should be checked to ensure that the unit s electrical characteristics and the supply characteristics agree The un...

Page 7: ...ly a reliable mercury thermometer or preferably an oven pyrometer 1 Place the thermocouple of the test instrument or reliable mercury thermometer in the center of the oven 2 Turn oven temperature control dial to 400 F 204 C In order to allow the oven temperature to stabilize the oven control must be allowed to cycle twice before taking a test reading 3 Check temperature reading control just as it ...

Page 8: ......

Reviews: