INSTALLATION Continued
Wall Mounted Salamanders, Cheese Melters
or Counter Mounted Salamander or
Cheese Melters
1. Clearance from combustible construction must be
six inches (6’) minimum at rear and six inches (6”)
minimum at sides.
Each gas appliance shall be located with respect to
building construction and other equipment so as
to permit access to the appliance. Such access and
clearance my be necessary for service and cleaning.
2. All models ending with suffix “C” must be fastened
to the counter top.
3. All models ending with suffix “W” are mounted to
a vertical surface using the mounting kit as shown
below. The salamanders are shipped with the wall
mounting kit already attached to the appliance.
4. Provisions for gas connections, bottom or rear,
should be taken into consideration at time of
installation.
Ventilation and Air Supply
Proper ventilation is highly important for good operation.
The ideal method of ventilation a Salamander Broiler is
the use of a properly designed canopy hood which should
extend six inches (6”) beyond all sides of the appliance
and six (6) feet six (6) inches from the floor.
A strong exhaust fan will create a vacuum in the room,
for an exhaust system to work properly, replacement air
must enter the room in which the vent is located. the
amount of air which is exhausted must equal the amount
entering, (make-up air).
All gas burners and pilots need sufficient air to operate
and large objects should not be placed in front or on top
of the broiler which would obstruct the air flow through
the front of the broiler.
FOR YOUR SAFETY never place any type of object
on top of the salamander broiler or cheese melters. The
top of the broiler will exceed 1000º F. It could cause
severe burns or fire and obstruct ventilatio
n
Clearances:
From Combustible material 6” sides and rear. A clearance
of 0.0” to non combustible construction as sides & rear
is acceptable, for the Salamander, The Cheese melter is
not suitable for installation on a combustible floor.