Gas Pressure & Individual Burner Input Rates
North America
Garland GF Series
Nat.,
4.5” wc Manifold
LPG,
10” wc Manifold
BTU/h
BTU/h
Open Top (Flame Failure)
26,000
26,000
Target Top 36” models only, per section
3@10,333
3@10,333
Hot Top FF (in lieu of 2 Open Top Burners)
18,000
18,000
Griddle (in lieu of 2 Open Top Burners)(Tstat)
18,000
18,000
Raised Griddle Broiler (3 burners)
3 @11,000
3 @11,000
26” Oven Burner (H-Cast)(Standard or Convection)
38,000
32,000
Space Saver Oven (H-Cast)
32,000
28,000
CE & General Export
Garland GF Series
Nat. (G20),
11.2 mbar Manifold
LPG (G31),
24.9 mbar Manifold
kW
kW
Open Top (Flame Failure)
7.6
7.6
Hot Top FF (in lieu of 2 Open Top Burners)
5.3
5.0
Target Top “36” models, only per section
Griddle (in lieu of 2 Open Top Burners)(Tstat)
5.3
5.3
Raised Griddle Broiler (3 burners)
3 @ 3.0
3 @ 3.0
26” Oven Burner (H-Cast)(Standard or Convection)
11.1
9.3
Space Saver Oven (H-Cast)
9.4
8.2
Reduced Input Rates
Approximate input ratings for adjustable top burners set at LOW:
Garland GF Series
NAT(G20)
LPG(G31)
kW
m
3
/h
kW
m
3
/h
Open Top Burner (Flame Failure)
2.0
0.21
4.2
0.17
Hot Top (Flame Failure)
2.75
0.29
4.9
0.20
Griddle (Tstat)
3.0
0.32
2.0
0.08
Raised Griddle Broiler (Total Of 3 Burners)
3.0
0.32
5.9
0.24
Target Top
2.7
0.28
4.0
0.16
Note: Manifold pressure is to measured at the test spigot located on the 3/4” gas manifold pipe.