Section 7: APPLICATION INFORMATION

 

7.20 

Vacuum System for Vacuum Chamber, Glove Box, Annular Space & Transfer Line:

 

 

- 2585B-50

 

 

- 2585C-50

 

 

- 2585C-56

 

7.21 

System Components

 
 
 
 
 
 
 
 
 
 
 
 
  

7.22 

 System Operation

The vacuum system provides high throughput 

fl ow which enables aspiration for applications up to 96 well formats. The 

attached inlet trap is provided to inhibit the accidental ingestion of liquid into the pump.

Vacuum level is preset at 26”Hg when the inlet is plugged with a rubber stopper. The vacuum gauge provided allows to check 
the vacuum level -- that is pressure below atmospheric. Please keep in mind that atmospheric pressure tends to vary from 
day to day. As a result of this variability, the dial vacuum gauge will indicate slightly diff erent maximum vacuum readings 
from day to day.

The preset vacuum level may be adjusted by opening or closing the orifi ce. A small leak through the orifi ce is provided 
to allow easy restart of the pump if you are turning off  then immediately turning on the pump as is found with some cell 
harvesting applications.

Adjust the vacuum using the screw located on top of the orifi ce. The deeper vacuum is particulary useful for removing sticky 
or viscous substance. If you close off  the orifi ce, please keep in mind this will lead to restart problems if you are turning off  
then immediately turning on the pump. If you encounter a restart problem after closing the orifi ce, you will need to incorporate 
into your procedure bringing the cell harvester up to atmospheric prior to restarting of the pump.

Qty.

2585

Description 

1

1415B

Replacement Jar

1 or 1

638788

Vacuum Gauge, kPa / in. Hg.

633210

Vacuum Gauge, cm Hg. / in. Hg.

639524

Vacuum Gauge, 0-30 in Hg/0-76cm Hg

Summary of Contents for Welch 2580B-01

Page 1: ...0B 50 2580C 50 2585C 02 2585C 05 2585C 50 2585C 55 2585C 57 Warning Not recommended for pumping acid base or organic vapors or gases Warning Be sure to properly identify intake and discharge before us...

Page 2: ...ons are found where failure to observe the instruction could result in damage to the equipment associated equipment and process These units con rm to the SI International system of units of measuremen...

Page 3: ...ions 3 01 Speci cation Chart Section 04 Motor Power Speci cations Features 4 01 Motor Speci cation Chart 4 02 Changing the Voltage Settings for Global Motor Option on A Models 4 03 Changing the Voltag...

Page 4: ...ion II 5 I 20 CAUTION To reduce risk of electrical shock I 21 Do not disassemble Disassembly or attempted repairs if accomplished incorrectly can create electrical shock hazard Refer servicing to qual...

Page 5: ...or indirect moisture contact The pump should be located as closely to its system in order to utilize it most e ciently The pump is rated for indoor use only Maximum altitude 2000 meters Operating tem...

Page 6: ...rrected 2 23 Identi cation Symbols 2 24 Grounding Instructions This product should be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an...

Page 7: ...monly used to indicate vacuum level when operating in the rough vacuum range 0 to 29 9 Hg Dial vacuum gauges give negative pressure that is pressure below atmospheric The reference point for the gauge...

Page 8: ...s if you have droplets coming out of the exhaust port If you see droplets of water Welch recommends you use a cold trap to capture the water before entering the pump or dilute the water vapor stream b...

Page 9: ...suspected area with a thick soap solution Escaping air will produce soap bubbles 3 14 Operating Pressure Range Model 2581 Dry Vacuum Pumps are designed to be run from atmospheric to their maximum vacu...

Page 10: ...n for the condition of the pump is the determination of its maximum vacuum capability This can be accomplished by blocking of the intake and reading the vacuum level on the gauge See Section 2 8 5 11...

Page 11: ...30 5 12 0 30 5 Shipping Weight lbs 27 5 27 5 Kg 12 5 12 5 Shipping Dimensions L in Inches cm 19 5 49 5 19 5 49 5 W in Inches cm 20 5 52 0 20 5 52 0 H in Inches cm 16 0 40 6 16 0 40 6 Catalog Number C...

Page 12: ...12 6 11 Pumping Speed Curves...

Page 13: ...13 6 12 Dimensional Drawing Dimensions of Pump Model 2580 2585 inches A B C D E F G H I J K L M N 12 5 11 69 7 37 5 25 10 5 8 5 9 5 8 75 3 06 0 75 4 62 0 75 4 5 6...

Page 14: ...0K 04 1 2 Note 1 Connecting Rod Assembly 2 2 2 Note 1 O Ring Valve Plate 2 2 3 2 Note 1 O Ring Connector Tube 4 4 4 1 Note 1 Head Screw 8 5 2 Note 1 Rubber Suction Feet 4 6 2 Note 1 Valve Plate Assemb...

Page 15: ...maximum vacuum readings from day to day The preset vacuum level may be adjusted by opening or closing the ori ce A small leak through the ori ce is provided to allow easy restart of the pump if you a...

Page 16: ...erative No other warranties are expressed or implied The method of executing this warranty servicing adjusting repairing or replacing shall be at the discretion of Gardner Denver Welch Vacuum Technolo...

Reviews: