SHIPPING WEIGHTS

LBS.  [kg]

            MODEL

RHP13

RHP20

Weight

57  [25.9]

65  [29.5]

DIMENSIONS

INCHES   [mm]

MODEL

RHP13 

RHP20

A

14  [356]

14  [356]

B

16 1/8  [410]

16 1/8  [410]

C

15  [381]

15  [381]

D

2  [51]

2  [51]

E

8 1/16  [204]

8 1/16  [204]

F

2  [51]

2  [51]

G

2 1/16  [52]

2 1/16  [52]

H

2 1/8   [54]

2 1/8   [54]

J

 2 [51]

2  [51]

K

1 3/4  [44]

1 3/4  [44]

L

12  [305]

12  [305]

M

5 3/8  [137]

5 3/8  [137]

P

2-1/2 [64]

2-1/2 [64]

OUTLET

FAN AIR FLOW

INLET

B

   FRONT  VIEW

 TOP VIEW

C

MINIMUM CLEARANCE
FOR FREE AIR FLOW
BOTH SIDES

   E

D

  M

   A

L

RIGHT SIDE VIEW

POWER ON (GREEN)

HIGH TEMP.
(RED)

ELECTRICAL
BOX

SEPARATOR
(INSULATED)

K

  H

J

 G                          F

KEY SLOTS  (FOR
WALL MOUNTING ON
CABINET BACK)

P

WALL MOUNTING SLOT (BACK)
(USED WITH HANGER BRACKET
ASSEMBLY ONLY)

AIR INLET/OUTLET
(3/8" OD)

CONDENSATE
DRAIN
(1/4" OD TUBE)

DIMENSIONS / WEIGHTS

Models RHP13 and RHP20

NOTE:  Dimensions and Weights are for reference only.
Request certified drawings for construction purposes only.

Summary of Contents for RHP Series

Page 1: ...re containing device Do not exceed maximum operating pressure as shown on equipment serial number tag Make certain equipment is depressurized before servicing 2 ELECTRICAL This equipment requires elec...

Page 2: ...he air with an aftercooler AIR INLET AIR OUTLET AIR OUTLET AIR INLET MODELS RHP64 RHP100 MODELS RHP13 RHP20 AIR INLET MODELS RHP93 RHP178 MODEL RHP50 AIR OUTLET AIR OUTLET AIR INLET B Air Outlet Conne...

Page 3: ...continuous duty service However when solenoid is energized for a long period the coil enclosure becomes hot and can be touched with the hand for only an instant This is a safe operating temperature C...

Page 4: ...tenance A Filter Sleeve Replacement The separator assembly contains a coalescing filter sleeve which requires replacement yearly or when excessive pressure drop is experienced across the dryer whichev...

Page 5: ...serial number tag Suction Pressure Setting controlled by hot gas by pass valve psig barg 31 5 2 2 31 5 2 2 Air Flow Across Condenser cfm 60 Hz 50 Hz 235 196 235 196 Minimum Maximum Operating Condition...

Page 6: ...2 4 17 5 Branch Circuit Fuse Size amps 15 20 25 Watts 35 F Evaporator 100 F Ambient 465 815 1060 Overload Thermal Current Auto reset Nominal Voltages 208 230 1 60 Max Min Voltage 253 207 253 187 253 1...

Page 7: ...1 2 64 2 1 2 64 OUTLET FAN AIR FLOW INLET B FRONT VIEW TOP VIEW C MINIMUM CLEARANCE FOR FREE AIR FLOW BOTH SIDES E D M A L RIGHT SIDE VIEW POWER ON GREEN HIGH TEMP RED ELECTRICAL BOX SEPARATOR INSULAT...

Page 8: ...1 589 819 495 737 394 41 38 92 64 311 52 81 230 NPT RHP178 500 23 3 16 32 1 4 19 1 2 29 15 1 2 1 5 8 1 1 2 2 1 4 2 1 2 2 1 2 3 7 8 9 1 16 3 4 1 1 2 589 819 495 737 394 41 38 57 64 64 98 230 NPT RHP100...

Page 9: ...on functioning fan motor or fan control switch c Water cooled models Cooling water temperature too high or flow too low faulty water regulating valve clogged water strainer Blow out system with dry ai...

Page 10: ...28 2 G4140 227 17 G4140 227 17 G4140 227 17 Condenser air cooled G4130 110 26 G4130 110 26 G4130 110 26 G4130 111 18 G4130 111 18 G4130 111 18 Dryer Strainer G4130 165 14 G4130 165 14 G4130 165 14 G41...

Page 11: ...4130 138 13 G4130 138 13 G4130 138 13 G4130 138 13 G4130 138 13 Condenser water cooled G4130 112 11 G4130 112 11 G4130 134 36 Water Control Valve G4130 145 20 G4130 145 20 G4130 145 22 Water Strainer...

Page 12: ...paired or replaced under warranty shall be warranted for the unexpired portion of the warranty applying to the original product The foregoing is the exclusive remedy of any buyer of the manufacturer s...

Reviews: