background image

 

POWER TAKE  OFF & HYDRAULIC PUMP: 

 

1. Mount power take off,and brace hydraulic pump per manufacturers instructions. 

 

2. Ensure that the female spline of power take off is filled with grease. 

 

3. Mount hydraulic pump to P.T.O. using only capscrews provided. 

Note  : To avoid  premature  spline  wear  of  the  pump  and  PTO from  torsional vibration consult the engine 

manufacturer for  the correct  engine  speed  (based  on  application) that  will  reduce  torsional vibration. 

 

 

SUCTION LINE INSTALLATION GUIDELINES: 

Special attention should be given to applications utilizing a double suction or large diameter piping. When  
excessive loading or insufficient support of the suction piping exists, reservoir fatigue fractures, loss of oil,  
and decreased hose life are likely to occur. 

 

1. For double suction applications, is the weight and length of pipe work (fittings) is excessive? If so,  
  shorten the piping to reduce vibration and add support brackets to compensate for the added weight. 
   Additional support brackets should be attached to a common point with the Hyrdrapak so that flexing  
  of the truck frame and vibration does not induce additional stress on the Hydrapak.   

 

2  On direct coupled double suction piping, if mounting conditions do not accommodate additional  
  support brackets, consider line mounting a pipe "Y" to fill the need for a double suction. When line  
  mounting the "Y", a single section of large diameter hose can be fitted to the reservoir suction fitting 
  leading into the "Y" downstream.  Appropriately sized piping can then exit the "Y" and lead into the  
  pump inlet sections. Always make sure the "Y" pipe is supported and consideration is given to the  
  remaining points.  

 

 

MOUNTING HYDRAPAK: 

Behind the cab is the preferred mounting method. 
Frame rail mount is the secondary choice. 

 

1. Drill 7/16

” dia. holes as shown in Fig.1.  Use the capscrews, washers and nuts supplied to mount the Hydrapak. 

 

2. Be sure to allow 4

” of space between radiator and any solid obstruction that will effect air flow into radiator. 

 

3. Radiator must be shielded from rocks and road debris. 

 

HYDRAULIC HOSES & FITTINGS: 

1. Do not use thread tape or pipe dope as this will contaminate the hydraulic system. 

 

2. All hoses are customer supplied.  Fit all hoses as per separate system drawings provided by Drum. 

 

3. All high pressure hoses must have a working pressure rating equal to or higher than the hydraulic system relief valve 

setting. 

4. The suction hose must be suitable for  28

”Hg vacuum service. 

 

5. Hoses must have proper support near the Hydrapak to reduce loading from hose and fluid weight.  
  Unsupported hoses pull on the welded connection fittings of the reservoir and may result in reservoir  
  stress fractures and shortened hose life. 

 

6. Proper installation of the hoses should include a slight bend in the hoses near the connections. This  
  allows them to flex, reduce vibration stress and hose shrinkage under load. 

 

7. All hoses should use the largest bend radius possible to reduce pressure drop and loading. Always  
  follow the hose manufacturer's recommendations for hose duty and bend radius. If an excessively  
  tight bend is required, consider using a section of rigid pipe such as a street 90 with increased pipe  
  diameter. 

 

Summary of Contents for MH3 HYDRAPAK

Page 1: ...OPERATION MAINTENANCE and INSTALLATION MANUAL 40 G P M 3500 P S I MH3 HYDRAPAK 999042002 VERSION 03 February 3 2015...

Page 2: ......

Page 3: ...oil Use a paint filter as a strainer while filling 3 After Hydrapak is filled check for hydraulic system leaks 4 Slowly raise the clutch while the engine is running to engage the P T O and pump Stop...

Page 4: ...sized piping can then exit the Y and lead into the pump inlet sections Always make sure the Y pipe is supported and consideration is given to the remaining points MOUNTING HYDRAPAK Behind the cab is...

Page 5: ...chart High pressure from hydraulic pump to Hydrapak Note 4 of space shown above must be maintained between radiator and any obstructions Radiator must be shielded from rocks and road debris Note for s...

Page 6: ...ns This type of Hydrapak mounting will provide good system performance provided that there are no rises in the suction line above the Hydrapak reservior Note pressure drop calculations must be perform...

Page 7: ...5 HYDRAULIC FILTER 306000206 1 SPIN ON STYLE 26 CAP SCREW 75A10Z 4 5 16 18 X 1 GR5 PLATED 27 NYLOCK NUT 236105400 4 5 16 18 PLATED 28 LOCK WASHER 405757 4 5 16 GR 5 S S 29 LOCK WSHER 240004400 3 1 4 G...