13-25-629 v03 Page 11
SECTION 2
INSTALLATION
GENERAL
- On receipt of the unit, check for any damage that may have been incurred during transit.
Report any damage or missing parts as soon as possible.
Do not electric weld on the compressor or base; bearings can be damaged by
passing of current.
LIFTING UNIT
- Proper lifting and/or transporting methods must be used to prevent damage. Unit may
be moved into location by lift truck.
Lift compressor unit under base only. Do not use other places such as motor,
compressor or discharge manifold piping as lifting points.
The eyebolts or lugs provided on the motor are for lifting the motor only and
should not be used to lift any additional weight. All eyebolts must be securely
tightened. When lifting the motor the lifting angle must not exceed 15°. Failure
to observe this warning may result in damage to equipment or personal injury.
Compressor, air/oil reservoir, separator chamber and all piping and tubing may
be at high temperature during and after operation.
LOCATION
(Figure 2-1) The compressor must be installed where it is protected from rain, snow and
freezing temperatures, in a clean, well-lighted, well-ventilated area with ample space all around for
maintenance. Select a location that provides a cool, clean, dry source of air. In some cases, it may be
necessary to install the air filter at some distance from the compressor to obtain proper air supply.
AIR-COOLED UNIT - A combination oil/air cooler is supplied as standard equipment on all air-
cooled units. A shaft driven axial fan supplies the ventilation needs for the oil/air cooler and
electric motor cooling (
Figure 1-2). Air is drawn into the unit through the left side panel, over the motor and discharged through
the cooler cores. Do not block the air flow to and from the unit. Allow three and one half (3-1/2) feet to
the nearest obstruction on the control box end of the unit. Allow two (2) feet to the nearest obstruction
above and on other sides of unit.
Summary of Contents for L4-5C
Page 27: ...13 25 629 v03 Page 27 FIGURE 4 5 WIRING DIAGRAM 380V 60 Hz 303ECA546 B Ref Drawing Page 1 of 3...
Page 28: ...13 25 629 v03 Page 28 FIGURE 4 6 WIRING DIAGRAM 380V 60 Hz 303ECA546 B Ref Drawing Page 2 of 3...
Page 29: ...13 25 629 v03 Page 29 FIGURE 4 7 WIRING DIAGRAM 380V 60 Hz 303ECA546 B Ref Drawing Page 3 of 3...
Page 30: ...13 25 629 v03 Page 30 FIGURE 4 8 WIRING DIAGRAM 575V 305ECA546 A Ref Drawing Page 1 of 3...
Page 31: ...13 25 629 v03 Page 31 FIGURE 4 9 WIRING DIAGRAM 575V 305ECA546 A Ref Drawing Page 2 of 3...
Page 32: ...13 25 629 v03 Page 32 FIGURE 4 10 WIRING DIAGRAM 575V 305ECA546 A Ref Drawing Page 3 of 3...
Page 61: ...13 25 629 v03 Page 61 Figure 9 5 Compressor Module Hardware...