8. Commissioning
34
8.5
Commissioning after malfunction
NOTICE
Do not switch the screw compressor on
repeatedly without having rectified the
malfunction, since this may cause considerable
damage to the machine.
Re-start after an automatic shutdown due to a
malfunction as follows:
•
Faults are shown as text in the compressor control
GD Pilot TS "fault memory" display menu.
Turn master switch off and secure it from being
switched on again.
•
Eliminate fault.
•
Turn master switch on.
•
Acknowledge the fault in the fault memory menu.
After the acknowledgement, the message [READY
TO START] appears on the display, unless another
fault is present.
•
Press START button [ I ] (-2- Fig. 17).
8.6
Shutoff
To switch off the compressor use the O key (-3- Fig. 17)
and not the EMERGENCY STOP button. After shutdown
the compressor has a run on time of 30-50 seconds (soft-
stop).
NOTICE
The unit may only be shut down using the
emergency stop button in real emergencies.
When shutting down normally, please use the
O key.
8.7
Emergency stop
The EMERGENCY STOP button is situated next to the
GD Pilot TS. It is used to immediately shut down the
unit. Only use the EMERGENCY STOP button (-7- Fig.
17) to shut down the unit in emergencies. When
shutting down normally, always use the [O] key.