Transport and installation
4
January 2017
America
27 /72
Air-cooled
systems
50 Hz
60 Hz
L160
4186 kg /
9229 lbs
4186 kg /
9229 lbs
L200
4415 kg /
9733 lbs
4415 kg /
9733 lbs
L250
4625 kg /
10196 lbs
4625 kg /
10196 lbs
L290 110
(direct drive)
4500 kg /
9921 lbs
4500 kg /
9921 lbs
L290
4650 kg /
10251 lbs
4650 kg /
10251 lbs
L160RS
4378 kg /
9652 lbs
4378 kg /
9652 lbs
L200RS
4573 kg /
10082 lbs
4573 kg /
10082 lbs
L250RS
4669 kg /
10293 lbs
4669 kg /
10293 lbs
L290RS
4684 kg /
10326 lbs
4684 kg /
10326 lbs
Water-cooled
systems
L160
4120 kg /
9083 lbs
4120 kg /
9083 lbs
L200
4330 kg /
9456 lbs
4330 kg /
9456 lbs
L250
4490 kg /
9899 lbs
4490 kg /
9899 lbs
L290 110
(direct drive)
4340 kg /
9568 lbs
4340 kg /
9568 lbs
L290
4490 kg /
9899 lbs
4490 kg /
9899 lbs
L160RS
4270 kg /
9414 lbs
4270 kg /
9414 lbs
L200RS
4460 kg /
9832 lbs
4460 kg /
9832 lbs
L250RS
4520 kg /
9965 lbs
4490 kg /
9899 lbs
L290RS
4520 kg /
9965 lbs
4490 kg /
9899 lbs
4.2
Storage
Storing compressors.
The compressor should be stored in a dry area,
heated if possible. This applies especially to the
winter months.
NOTICE
Damage to property
Damage to property due to exceeding the
permissible temperature range
➯
Where there is a risk that the permissible
temperature limits of +2 ...+65 °C / +36 ...
+149 °F could be exceed or underrun,
contact Gardner Denver.
Corrosion protection
All compressors are protected at the factory
against corrosion for shipping and short-term
storage prior to commissioning. If compressors
are stored for longer than 6 months, additional
preventive measures must be taken.
Compressors that will be out of service for an
extended period of time must also be protected
against corrosion.
4.3
Installation
Requirements for the installation site
The compressor must be installed with full contact
on a foundation with sufficient structural strength.
The bearing surface must be level to within 3 mm /
0.12 ".
The installation site (compressor room) should be
of sufficient size that on side ("A") a clearance of
1 m/39 “ and on side ("B") a clearance of 1.5/59
“ may not be undershot. The clearance above
the compressor should be 1.50 m/59” at least.
There should also be appropriate access space for
maintenance work.
Fig. 4-2: Installation / clearances
Set up the compressor so that there is
sufficient access and that the required cooling
is ensured.
Do not block the air inlet.
Avoid moisture.
Summary of Contents for L160 110A V2
Page 1: ...User manual Screw compressor L160 L290 V2 L160RS L290RS V2 America ZS1149274 03 January 2017...
Page 7: ...Foreword 1 January 2017 America 7 72 1 6 Rating plate Fig 1 1 Rating plate...
Page 69: ...Appendix 9 January 2017 America 69 72...
Page 70: ...9 Appendix 70 72 America January 2017...