13-8-621 Page 35
SECTION 6
AIR FILTER
Figure 6-1 – AIR FILTER
STANDARD DUTY AIR FILTER
(Figure 6-1) - Replacement instructions are given in the following
sections:
DANGER
Compressor, air/oil reservoir, separation chamber and all piping and tubing
may be at high temperature during and after operation.
WARNING
The air filter element can not be cleaned or reused.
Filter Element
- The element should be replaced when inspection indicates an accumulation of dirt on
the outside of the element. Inspect every few days until experience determines the proper time interval
for servicing.
To Service:
1. Be certain the unit is off and that no air pressure is in the air/oil reservoir. The compressor package
will automatically blow down in about 2 minutes.
2. Close the air service valve located after the compressor package discharge.
3. Disconnect, lockout and tagout the power supply to the starter.
4. Remove the air filter cover (Figure 6-1).
5. Clean the inside of the air filter housing.
6. Install new air filter element and the air filter cover.
7. Open the air service valve.
Summary of Contents for INTEGRA EFC99A
Page 9: ...13 8 621 Page 2 Figure 1 2 COMPRESSOR ILLUSTRATION 302EFC797 A Ref Drawing...
Page 12: ...13 8 621 Page 5 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 13: ...13 8 621 Page 6 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Page 29: ...13 8 621 Page 22 4 3 WIRING DIAGRAM 300EFC546 B Ref Drawing Page 1 of 2...
Page 30: ...13 8 621 Page 23 300EFC546 B Ref Drawing Page 2 of 2...