HF-7-602 Page 53
61. Remove protective sleeve from drive shaft.
62. Attach sump cover to gear end bearing housing using four socket head cap screws (31) in two
center holes on each long side of cover. Install remaining screws (27). Tighten all screws.
Torque: 37 ft-lbs
63. Install plugs (32) in the four instrument holes in the air cylinder near the inlet and discharge ports.
64. Install oil level sight glass (28) in appropriate location each sump cover. Apply Loctite 243 to
threads of each sight glass.
65. Install magnetic plugs (41) in appropriate holes of each sump cover.
66. Install plugs (26) in remaining holes in each sump cover.
Note
: There are no external sump breathers used on this blower.
67. Install four mounting feet (38) to air cylinder with eight screws (30). Feet should be pointing
outward from air cylinder center line. Tighten screws.
Torque: 100 ft-lbs.
68. Measure run out of drive shaft using a dial indicator and a magnetic base.
Drive Shaft Runout: .001" max
69. Install drive shaft key (35) into keyway in drive rotor shaft.