13-17-621 Page 97
9000SP or similar lubricant.
High Temp
: Oil Change Timer counts down more slowly at high temperature. Use with
AEON 9000TH or similar lubricant.
Table 43: Oil Change Multipliers
Oil Change Multipliers
Oil Aging Clock
Multiplier
Standard Oil Temperature
Break Points
High Temp Oil Temperature
Break Points
X1
< 180°F (82°C)
< 210°F (99°C)
X 1.3
180°F - 189°F (82°C - 87°C)
210°F - 219°F (99°C - 104°C)
X 2
190°F - 198°F (88°C - 92°C)
220°F - 228°F (104°C - 109°C)
X 4
199°F - 216°F (93°C - 102°C)
> 229°F (109°C)
X 8
217°F - 234°F (103°C - 112°C)
X 16
> 234°F (112°C)
4.7.1.6 System Voltage:
Each system is designed to operate at a certain voltage and in some cases a range of voltages. The User
can configure the operating voltage by touching the voltage value and enter the
System Voltage
on the
number-pad. Figure 131 below shows setting the
System
Voltage
to
460V
.
Figure 131: System Voltage
4.7.1.7 Motor SFA:
The
Motor Service Factor Amperage
value is the amount of current the motor will draw when running at
the full service factor. This value can be obtained from motor manufacturer of the motor used in the system
or listed on the motor nameplate. Figure 132 shows setting the value of
Motor SFA
as
195.2 A.
This value
is used on fixed speed machines where a motor current analog input is present.