The effects of corrosion, erosion and normal wear and tear are specifically excluded. Performance warranties are limited to those 

specifically stated within the Company's proposal. Unless responsibility for meeting such performance warranties are limited to specified 
tests, the Company's obligation shall be to correct in the manner and for the period of time provided above. 

THE COMPANY  MAKES NO  OTHER WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER, EXPRESSED OR 

IMPLIED,  EXCEPT  THAT  OF  TITLE,  AND  ALL  IMPLIED  WARRANTIES  OF  MERCHANTABILITY  AND  FITNESS  FOR  A 
PARTICULAR PURPOSE, ARE HERBY DISCLAIMED. 

Correction by the Company of nonconformities whether patent or latent, in the manner and for the period of time provided above, 

shall constitute fulfillment of all liabilities of the Company for such nonconformities whether based on contract, warranty negligence, 
indemnity, strict liability or otherwise with respect to or arising out of such Equipment. 

The Purchaser shall not operate Equipment which is considered to be defective, without first notifying the Company in writing of its 

intention to do so. Any such use of Equipment will be at Purchaser's sole risk and liability. 

Note that this is Gardner Denver standard warranty. Any warranty in force at the time of purchase of the equipment or negotiated 

as part of the purchase order may take precedence over this warranty. 

 

1.  GENERAL INFORMATION 

 

1.1 FUNCTIONAL DESCRIPTION 

Gardner Denver refrigerated air dryers remove moisture from compressed air. Moisture is detrimental to pneumatically operated 

appliances, controls, instruments, machinery and tools.  

Compressed air enters the patented aluminum heat exchanger where it is cooled down to the dew point temperature in two different 

stages: In the first air/air sector compressed inlet air is cooled thanks to the colder compressed air coming out counterflow from the 
condensate separator. In the second refrigerant / air sector, compressed air temperature is further lowered to the dew point temperature. 
During this two stages almost all the oil and water vapours contained in compressed air are condensed to liquid and successively be 
separated from the compressed air in the condensate separator and drained out by the automatic drain. At this point the obtained cold 
air re-enters counterflow the initial air / air exchanger and it is reheated by the inlet hot air with the consequence of energy rec overing 
and also reduction of the relative humidity contained in the outflowing air. 

This dryer can be easily installed into various pneumatic systems in which dry air is required or desired. Please refer to Principles 

of Operation for complete operating details. 

 

 

 

The dryer comes provided with all the control, safety and adjustment devices, therefore no auxiliary devices are needed. 

A system overload not exceeding the maximum operative limits can worsen the operational performance of the dryer (high 
dew point), but it will not affect its safety. 

The electric diagram (attachment B) shows the minimum protection degree IP 42. 
 
Improper grounding can result in electrical shock and can cause severe injury or death. 
This product must be connected to a grounded, metallic, permanent wiring system or an equipment-grounding terminal or 
lead on the product. 
All grounding must be performed by a qualified electrician and comply with national and local electrical codes. 
In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the 
electric current. 
Ground must be established with a bare grounding wire sized according to the voltage and minimum branch circuit 
requirements.  
Ensure good bare metal contact at all grounding connection points, and ensure all connections are clean and tight.  
Check grounding connections after initial installation and periodically thereafter to ensure good contact and continuity has 
been maintained. 
Check with a qualified electrician or service technician if the grounding instructions are not completely understood, or if in 
doubt as to whether the product is properly grounded. 
 

 

 

This  dryer  is  designed  to  work  only  with  compressed  air.  For  a  different  use,  please  contact  your 
distributor Gardner Denver. 

 

 

1.2 USE OF THE MACHINE IN SAFE CONDITIONS 

This  system  has  been  designed  and  manufactured  in  compliance  with  the  European  safety  directive  in  force,  therefore  any 

installation, use and maintenance operations must be performed respecting the instructions contained in this manual. 

Because an air dryer is pressurized and contains rotating parts, the same precautions should be observed as with any piece of 

machinery of this type where carelessness in operation or maintenance could be hazardous to personnel. In addition to obvious safety 
rules that should be followed with this type of machinery, safety precautions as listed below must be observed. 

Summary of Contents for GDD100F

Page 1: ...02 2022 Copyright 2022 Gardner Denver All rights reserved 1 10 DIRECT EXPANSION COMPRESSED AIR DRYERS Operators Manual GDD4F GDD7F GDD9F GDD12F GDD18F GDD24F GDD30F GDD37F GDD43F GDD50F GDD60F GDD80F...

Page 2: ......

Page 3: ...lation 4 3 START UP 3 1 Control panel 4 3 1 1 Keys function 5 3 1 2 Condensate discharge parameters programming 6 3 1 3 Anomaly warning 6 3 1 4 Remote signalling alarm 7 3 2 Before start up 7 3 3 Star...

Page 4: ...Cod 710 0138 72 00 Rev 10 12 2021 Copyright 2021 Gardner Denver All rights reserved...

Page 5: ...o the risk of electric shock Condensate drain point Rotation direction of the fan Pay particular attention to the risk of moving parts Explosion risk Lifting point Don t lift from this point Attention...

Page 6: ...re enters counterflow the initial air air exchanger and it is reheated by the inlet hot air with the consequence of energy recovering and also reduction of the relative humidity contained in the outf...

Page 7: ...attempt to lift heavy objects without proper lifting equipment i e crane hoist slings or fork truck Lifting any unit without proper lifting equipment may cause serious injury Use fork lift channels wh...

Page 8: ...isolation switch if present The control panel will show the message OFF indicating that the line and control voltages are available Start sequence The dryer will initially start by pressing and holdi...

Page 9: ...t point it increases the displayed value of one unit per second during the first 10 seconds than of one unit every 0 1 sec ON OFF Pressed it activates or deactivates the dryer When the dryer is deacti...

Page 10: ...the dryer WARNING FOR USER IT S FORBIDDEN TO ATTEMPT TO MODIFY THE OTHER CONFIGURATION PARAMETERS OF THE ELECTRONIC CONTROLLER WITHOUT AUTHORIZATION AND COLLABORATION OF Gardner Denver S AUTHORIZED DI...

Page 11: ...ng the first working hours 3 3 START UP The operations specified below must be performed after the first start up and at each start up after a prolonged inactive period of time due to maintenance oper...

Page 12: ...ryer Replace elements as needed YEARLY OR EVERY 2000 HOURS OF OPERATION Check if the flexible tube used for condensate drainage is damaged and replace it if necessary Check if all connecting pipes are...

Page 13: ...essure switch Reset the high pressure switch Problems with cabling or with the electronic control board Check the cabling and the electronic control board if the trouble persists replace them Activati...

Page 14: ...xtremely delicate Do not remove the probe from its position In case of any kind of problem please contact your local Gardner Denver distributor Pic 3 drain solenoid valve When it is necessary Clean th...

Page 15: ...y mains 4 3 DECOMMISSIONING All work on the dryer may only be carried out by specialist personnel Follow this procedure if you need to shut down the dryer Stop the device and permanently isolate it fr...