13–9/10–641 Page 11
Length of Inlet Line
Diameter of Pipe Size
0 to 10 Feet (0 to 3 Meters)
Same as Compressor Inlet Opening
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 to 17 Feet (3 to 5 Meters)
One Size Larger Than Inlet Opening
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 to 38 Feet (5 to 11.5 Meters)
Two Sizes Larger Than Inlet Opening
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FIGURE 2–4 – INLET LINE LENGTHS
CONTROL PIPING – Control piping is not necessary
since the Electra–Screw
R
unit is factory wired and
piped for the control system specified.
INLET LINE – Where an inlet line is used between the
air filter and the compressor, it must be thoroughly
cleaned on the inside to prevent dirt or scale from enter-
ing the compressor. If welded construction is used,
the line must be shot blasted and cleaned to remove
welding scale. In either case, the inlet line must be
coated internally by galvanizing or painting with a mois-
ture and oil–proof sealing lacquer. Up to ten (10) feet (3
meters) in length, the inlet line should be the full size of
the inlet opening on the compressor. If an extra–long line
is necessary, the pipe size should be increased according
to Inlet Line Length Chart, FIGURE 2–4.
HEAT EXCHANGER (DOMESTIC)
Approx.
Water Temperature to Heat Exchanger
Water Pressure
Gallons/minute
Maximum
Drop @ 90
_
F
Water Flow
Water Temp.
HP
Model
60
_
F.
70
_
F.
80
_
F.
90
_
F.
GPM*
PSI
40 HP
EBHSH_
3.4
4.3
5.7
8.6
30.0
1.0
50 HP
EBHSJ_
4.1
5.1
6.8
10.2
30.0
1.5
60 HP
EBMSK_
5.0
6.2
8.3
12.5
40.8
2.0
75 HP
EBMSL_
6.0
7.6
10.1
15.1
40.8
1.5
100 HP
EBPSM_
8.4
10.5
14.1
21.1
40.8
5.0
100 HP
EAPSM_
8.4
10.5
14.1
21.1
40.8
5.0
FIGURE 2–5 – HEAT EXCHANGER (OIL COOLER) APPROXIMATE WATER FLOW
HEAT EXCHANGER (INTERNATIONAL)
Water Temperature to Heat Exchanger
Approx.
Liters/Second
Maximum
Water Press. Drop
Water Flow
@ 32
_
C. Water
KW
Model
16
_
C.
21
_
C.
27
_
C.
32
_
C.
L/S *
Temp. Bar
45 KW
EBMSK_
.32
.39
.52
.79
2.57
.14 Bar
55 KW
EBMSL_
.44
.54
.73
1.09
2.57
.10 Bar
75 KW
EBMSM_
.58
.73
.97
1.44
2.57
.35 Bar
* Flows exceeding “Maximum Water Flow” will cause severe erosion and will void unit warranty.