Page 12
Publication 4991460001 (May 2000)
Fig 9
To change the gearcase Oil:-
Remove the GRP cover by removing the four dome nuts and washers. (Fig 9) and
withdraw the cover.
Remove the 3/8’’ B.S.P. plug (Fig 9) and washer and drain the oil into a suitable container
5.2
Draining the Gearcase Oil
3/8’’ B.S.P Plug and
Dowty Washer
5
MAINTENANCE INSTRUCTIONS
5.1
Routine Maintenance
The service intervals stated below are based upon intermittent usage of the D9000 unit,
with total operating time of less than 5 hours/ day. For continuous operation, or operation
at high temperatures, a more frequent and more rigorous service schedule is required.
Consult your Drum distributor for details.
Monthly
-
Inspect Air Filters.
Check oil Level in Gearcase.(Page 13)
Check security of mounting bolts.
Check Drive Belt tension.(Page 9)
3 Monthly -
Check Relief Valve operation.(Page 13)
6 Monthly -
Inspect Inlet Air Filter, Clean or replace if necessary.(Page 14)
Yearly
-
Replace Air Filter.(Page 14)
Change Gearcase oil.(Page 12-13)
Grease Bearing Housing Caps.(Page 14)