13-21-608 Page 58
Discharge
Temperature
AEON 4000
Change Interval
AEON 9000 SP
Change Interval
Up to 180
°
F (82
°
C)
4000 hrs.
8000 hrs.
180
°
F to 190
°
F (82
°
C to 88
°
C)
3000 hrs.
6000 hrs.
190
°
F to 200
°
F (88
°
C to 93
°
C)
2000 hrs.
4000 hrs.
200
°
F+ (93
°
C)
1000 hrs.
2000 hrs.
Figure 5-7 – OIL CHANGE INTERVAL
DRAINING AND CLEANING OIL SYSTEM
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters.
Compressor, air/oil reservoir, separation chamber and all piping and tubing
may be at high temperature during and after operation.
Always drain the complete system. Draining when the oil is hot will help to prevent varnish deposits and
carry away impurities.
To drain the system, use one of the following methods:
1.
If the unit is not elevated high enough to use the oil reservoir drain line to drain oil, a small
hand, electric or air operated pump should be used to drain reservoir through the oil filler
opening or from the drain valve.
2.
If the unit is elevated so that the oil reservoir drain can be used, empty the oil reservoir through
the drain valve to a suitable container or sump.
3.
If the drained oil and/or the oil filter element are contaminated with dirt, flush the entire system:
reservoir, oil cooler, mixing valve and lines. Inspect the oil separator elements for dirt
accumulation; replace if necessary. If a varnish deposit exists, contact the factory for
recommendations for removal of the deposit and prevention of varnish.
Summary of Contents for AirSmart ELECTRA-SAVER
Page 13: ...13 21 608 Page 12 Figure 1 6 AIR OIL FLOW DIAGRAM 202EDM797 Ref Drawing...
Page 45: ...13 21 608 Page 44 Figure 4 14 WIRING DIAGRAM WYE DELTA 335EAQ546 A Ref Drawing Page 1 of 2...
Page 46: ...13 21 608 Page 45 335EAQ546 A Ref Drawing Page 2 of 2...
Page 47: ...13 21 608 Page 46 Figure 4 15 WIRING DIAGRAM LESS STARTER 336EAQ546 A Ref Drawing Page 1 of 3...
Page 48: ...13 21 608 Page 47 336EAQ546 A Ref Drawing Page 2 of 3...
Page 49: ...13 21 608 Page 48 336EAQ546 A Ref Drawing Page 3 of 3...
Page 53: ...13 21 608 Page 52 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 203EDM797 A Ref Drawing...
Page 78: ......
Page 79: ...NOTES...