13-8-638 Page 9
CAUTION
If the compressor unit base is raised above floor level, the space between the
floor and the base bottom must be closed with solid material all around to
prevent recirculation of hot air from the oil cooler end and over temperature
operation.
ENCLOSURE
- The compressor, electric motor, oil cooler and aftercooler are mounted inside the
enclosure.
Service panels are provided for maintenance access. Be sure to allow enough space around the unit for
the panels to be removed. Any of the enclosure panels may be removed by opening the latch and lifting it
up slightly.
DANGER
Do not operate the compressor with the fan and belt guard removed. Exposed
fan and belts may cause injury to personnel.
CAUTION
The enclosure doors and panels must be closed and latched while the
compressor is operating. Failure to close and latch the doors and panels will
cause high temperature shutdowns.
Figure 2-3 – COLD WEATHER INSTALLATION