7. TECHNICAL DATA
ZoneProtect
Unit
Value
Battery operation time (approx.) d
31
Battery charging voltage
V
5
Battery charging current
A
1
Battery charging time
h
6
IP Protection class
IPx4
Operating temperature range
°C
0 – 40
Operating Frequency Band
Hz
100 –
80000
Max. radiofrequency power
1)
mW
< 25
1)
Maximum active output power to antennas in the fre
quency band in which the radio equipment operates.
8. ACCESSORIES
GARDENA
Boundary wire
50 m /
150 m
Art 405860 /
Art 408860
GARDENA
Ground hooks
100 pieces
Art 409020
GARDENA
Con nectors
+ Connection
clamps
6 connectors
+ 3 connection
clamps
Art. 408920
9. SERVICE
Please contact the address on the back page.
6. TROUBLESHOOTING
Problem
Possible Cause Remedy
(L)
illuminates /
blinks / flashes
blue
Zone cable is
not connected
or cut.
v
Connect the
zone cable.
(L)
illuminates /
blinks / flashes
purple and the
mower is not in
ECO mode
Boundary cable
is not detected
or cut.
v
Check the
boundary
cable.
(L)
illuminates /
blinks / flashes
red
ZoneProtect
overtemperature.
Permanent error.
v
Put the Zone
Protect in the
shade and let
it cool down.
Contact the
GARDENA
Service.
(L)
flashes
white 5 times
every 10 sec
Battery is empty
or there is an
error or the zone
cable is broken /
unplugged.
v
Charge the
battery or
check the
zone cable.
Robotic lawn
mower crosses
the zone cable
Software transfer
error.
v
Press and hold
the button
(8)
for 15 seconds.
Zone Generator
function is not
enabled in the
mower menu /
app.
v
Enable the
Zone Generator
function in the
mower menu /
app.
Robotic lawn
mower stops
(Zone
Generator
Problem)
Battery is empty.
v
Charge the
battery.
ZoneProtect
overtemperature.
v
Put the Zone
Protect in the
shade and let it
cool down.
14
en