background image

13

G

12

G

Adaptable lamps

Light / Fountain Nozzle

Remote control

Pond aeration

Filling the filter tank 
with zeolith

Information

Example for application:

Underwater lighting of water jets and pond edges.

Products:

GARDENA Underwater Light

Art. No. 7951

GARDENA 

lightline Transformers

Example for application:

For installation in ponds and fountains.

Product:

GARDENA Light / Fountain Nozzle

Art. No. 7953

Example for application:

For operating water jets from the comfort of your patio or
your living room.

Products:

GARDENA Remote Control Set

Art. No. 7874

GARDENA Remote Control Socket

Art. No. 7875

Example for application:

To aerate the pond.

Product :

GARDENA Pond Aerator

Art. No. 7936

Zeolith fulfils the following functions:

.

Filters the water (

protection for the pump).

.

Bonds with excessive nutrients and causes their decomposition

by bacteria (

Ion exchange and the bonding of e.g. nitrate).

.

Helps to keep the pond clean and maintain the biological 

balance.

.

Provides stability for the pump 

GARDENA Zeolith, 1 l

Art. No. 7914

GARDENA Zeolith, 5 l

Art. No. 7915

Note :

To ensure the zeolith functions correctly, we recommend you 
replace or clean it every 6 months (e.g. in salt water).

.

Always unplug the pump first before working on it.

.

Before assembling system extensions first unscrew the pre-
assembled cascade and if necessary also the telescopic tube
of the pump and then screw one of the water jets on again 
(

the ball-and-socket joint ensures that the water jet is 

vertical).

.

Follow the Safety and Assembly Information attached to the
operating instructions.

Applications:
Examples – System Extensions – Product Recommendations

Example for application:

Water jets may be integrated into water features.

Model

Cascade

Water

Foaming

Water

Water-

Cascade

Bell

Jet Spray Fleur-de-Lis

fall

Rotating

Art.

7814 *

7816

7818

7820

7822

7823

No.

WP 600, 12 V

7850

××

××

××

WP 1200, 12 V

7856

××

××

××

××

××

××

* contained in delivery volume

Check line voltage. Data indicated on the type plate must match
technical data of the mains supply.

The pump must not be operated when there are people in the
water.

Swimming pools and garden ponds should be designed accord-
ing to international and national design regulations. Please 
consult a professional electrician.

Do not use the power cable to carry the pump or to pull the plug
out of the socket. Protect the power cable from heat, oil and
sharp edges.

Please unplug the pump after operation and before carrying out
any maintenance works.

The temperature of the liquid used must not be below 4 °C or
above 35 °C.

Sand and other abrasive substances in the liquid cause in-
creased wear and reduce the output of the pump.

GARDENA pumps and plug connections have been designed
exclusively for the use with 12 V low voltage. When connected 
to 230 V your life is at risk! Operate the pump only with the
delivered transformer.

Do not expose the transformer to direct sunlight.

Ensure that the transformer is positioned in a place safe from
flooding and at least 2 m away from the edge of the pond.

Please observe the local noise prevention regulations.

Check line voltage

Do not operate pump
when there are people 
in the water 

Swimming pools 
and garden ponds 

Do not use power cable 
to carry the pump

Disconnect plug

Temperature of the liquid
used

Wear and reduced 
output

Caution ! 
12 V low voltage 

Do not expose the 
transformer to sunlight

To place the transformer

Observe local noise 
prevention regulations

Water jets for 
26,5 mm (G 3 /4) thread 
connections

Summary of Contents for WP 600

Page 1: ...emploi Pompe pour jets d eau 12 V NL Gebruiksaanwijzing Waterspelpomp 12 V S Bruksanvisning Font n Pump Set 12 V I Istruzioni per l uso Pompa per giochi d acqua 12 V E Manual de instrucciones Bomba pa...

Page 2: ...ingebruikname van het apparaat zorgvuldig door Pagina Gebruiksaanwijzing 25 31 S L s igenom bruksanvisnin gen noggrant innan Du tar Din GARDENA Pump i bruk Sida Bruksanvisning 32 37 I Prima di metter...

Page 3: ...inner as well as salt water or food drinking water must not be pumped A For Your Safety The transformer should be operated via a residual current device with a residual current rating of 30 mA DIN VDE...

Page 4: ...r application Water jets may be integrated into water features Model Cascade Water Foaming Water Water Cascade Bell Jet Spray Fleur de Lis fall Rotating Art 7814 7816 7818 7820 7822 7823 No WP 600 12...

Page 5: ...ith the pressure joint being cated press it firmly and then turn it straight to the right Observe the markings 14 G Operation 1 Remove the pump from the filter basket and screw the regulator supplied...

Page 6: ...any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us and if the repairs were not carried out by a GARDENA Servic...

Page 7: ...gos de agua Garantibevis Springvandspumpe Wurde gekauft am H ndlerstempel Was purchased on Dealer s stamp Receipt Achet e le date et lieu d achat Cachet du revendeur Werd gekocht op Stempel van de han...

Page 8: ...apest Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S r l Via Donizetti 22 200...

Reviews: