background image

9

7. Changing the Battery

A

To ensure the Water Timer runs safely, only a 9 V alkali-
manganese battery (alkaline) type IEC 6LR61 must be used.

If the battery voltage falls below a 

certain level

the 

Batt

. indicator appears.

It is possible to initiate watering manually
even if the battery capacity is too low
(valve no longer opens), but programmed
watering times, however, are not initiated.

Even if the 

battery capacity is too low

to run a program, if the valve is

open it will be closed.

The battery voltage is tested 

during the opening pulse.

In this way you

can 

test the capability of the battery at any time.

To do this, simply

press the 

On / Off-man.

key. If the valve opens and the 

Batt

. indicator does

not appear then the battery does not have to be changed.

A

Previously set data is lost when replacing the battery.
Program the Water Timer subsequently again.

For notes on changing the battery see “Inserting the Battery”.

8. Notes on Safety and Operation

.

The minimum water output to ensure that the Water Computer 
functions correctly is 20 - 30 l / h.
For example, at least 10 x 2-litre Drip Heads are required to 
control the Micro-Drip-System.

.

To prevent water penetrating the battery compartment the Water
Timer must only be mounted in a perpendicular position with 
the sleeve nut pointing upwards.

.

Program the Water Timer with the tap turned off. In this way 
you can avoid getting wet when trying out the manual On / Off 
function. You can remove the control unit from the housing to 
program the Water Timer.

.

The Water Timer must only be used outdoors.
Warning ! The Water Timer must not be used indoors.

.

The Water Timer must be stored in a dry place away from frost
before the frosty season begins.

.

The max. temperature for the water flow is 40 °C.

8

You can start or end the watering prematurely at any time by pressing the

man.

key. The watering time is then 30 minutes.

Read / Change Program

To check the data, you can repeatedly press the 

O.K.

key to run through

the program levels. The levels are selected and checked consecutively.
This does not interrupt the current program cycle.

To change the data, proceed as described above.

Program Overview

Program

Cycle

Duration 

number

00

No program active

01

6 hours (4 times daily)

3 minutes

02

12 hours (twice daily)

3 minutes

03

12 hours (twice daily)

15 minutes

04

24 hours (once a day)

3 minutes

05

24 hours (once a day)

5 minutes

06

24 hours (once a day)

30 minutes

07

24 hours (once a day)

1 hour

08

2 days

5 minutes

09

2 days

30 minutes

10

2 days

1 hour

11

3 days

30 minutes

12

3 days

1 hour

13

7 days

1 hour

14

7 days

2 hours

Manual, programming-independent On / Off (man.)

Before and after entering data, you can operate the GARDENA Water
Timer electronic T 14 e manually, independent of the programmed data.
To do this, press the 

man.

key.

Press the MAN key once to activate watering for a maximum of 30 minutes
(LCD :

On

). Press the 

man.

key again to end watering.

·

Batt.

On

·

Off

·

28 .

.

88

3

·

Time 

·

Star

t

·

Cyc

le

Summary of Contents for Water Timer Electronic T 14 e

Page 1: ...ectronic T 14 e S Bruksanvisning Bevattningstimer electronic T 14 e NL Gebruiksaanwijzing Elektronische watertimer T 14 e D Gebrauchsanweisung Bew sserungsuhr electronic T 14 e FIN K ytt ohje Elektron...

Page 2: ......

Page 3: ...approx 1 year G 4 How the Water Timer Electronic Works This GARDENA Water Timer Electronic T 14 e allows you to set different watering cycles for different watering times independent of whether you ar...

Page 4: ...shing 2 You can enter the time using the man key e g 9 00 3 Use the O K key to confirm the hour you have entered and to allow you to enter the minutes 4 Select the minutes using the man key e g 23 5 C...

Page 5: ...getting wet when trying out the manual On Off function You can remove the control unit from the housing to program the Water Timer The Water Timer must only be used outdoors Warning The Water Timer m...

Page 6: ...inimum operating pressure is 1 bar the maximum operating pressure is 12 bar Check the filter in the sleeve nut 7 regularly and clean if necessary Avoid tensile strain Do not pull the hose connected to...

Page 7: ...ordance with the harmonised EU guidelines EU standards of safety and product specific standards This certificate becomes void if the unit is modified without our approval Description of the unit Water...

Page 8: ...se contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet S Garant...

Page 9: ...tca 22 1158 Budapest Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S r l Via D...

Reviews: