4. Putting Your Water Timer into Operation 

1. Turn battery cover

1

anticlockwise and remove battery 

holder

2

.

2. Insert 4 x LR-6-

AA

(

Mignon

) alkaline batteries

3

in the battery

holder.
Ensure that polarity is correct (+ /-).

3. Insert the battery holder

2

in the correct position and close the

battery cover

1

.

Both LEDs are illuminated for 2 seconds and the Water
Timer performs a self-test. The valve is closed automati-
cally during this process.

Make sure you exchange the batteries at the right time to prevent
the Water Timer failing due to low batteries when you are away for
longer periods of time.

Make sure that the time the batteries have been in operation and
the time you are planning to be away does not add up to more
than 1 year.

Even if the batteries are almost empty, the Water Timer ensures
that an open valve is always closed.

If both LEDs flash, the batteries are flat and must be replaced.

Inserting the batteries :

Battery warning :

2

1

3

Summary of Contents for T 1030 card

Page 1: ...GB S H CZ RUS GARDENA T 1030 card Art 1830 GB Operating Instructions Water Timer S Bruksanvisning Bevattningstimer H Haszn lati tmutat V zprogramoz ra CZ N vod k pou it Zavla ovac hodiny RUS...

Page 2: ...as well as the notes on safety For safety reasons children and young people under 16 as well as anyone who is not familiar with these operating instructions may not use the Water Timer v Please keep...

Page 3: ...anese alkaline batteries may be used The Water Timer will only run for approx 1 year if the new alkaline batteries has a nominal voltage of at least 1 5 V v Have the batteries checked before purchase...

Page 4: ...ly the control unit can be removed for programming The max temperature for the water is 40 C v Only use clear fresh water 3 Function The GARDENA Water Timer allows you to set different watering cycles...

Page 5: ...ld the programming card 2 Red LED Indicates a fault 3 Green LED Indicates the system is operating 4 Red button Start reading in the program Manual operation 5 Storage For storing the programming card...

Page 6: ...a self test The valve is closed automati cally during this process Make sure you exchange the batteries at the right time to prevent the Water Timer failing due to low batteries when you are away for...

Page 7: ...21 mm G 1 2 thread Connecting the Water Timer to taps with a 33 3 mm G1 thread 1 Screw the sleeve nut 4 of the Water Timer onto the thread of the tap by hand do not use pliers 2 Screw the threaded tap...

Page 8: ...ed area or place rain sensor with extension cable if necessary outside the watered area 2 Insert the sensor in the sensor connection 7 of the Water Computer 5 Operating Your Water Timer The time of da...

Page 9: ...le slide to the cycle required e g 24 hours every day 2 Insert programming card 8 in the card slot of the Water Timer 3 Press red button briefly The green LED flashes for 10 seconds 4 Remove programmi...

Page 10: ...t On rainy days the programmed watering cycle is often un necessary You can therefore stop the programmed watering cycle bad weather function The program set is retained on the programming card in thi...

Page 11: ...n the not in an unambiguous position programming card Both LEDs are flashing Battery level is too low v Insert new alkaline batteries Opening manually impossible Valve is blocked 1 Remove batteries 2...

Page 12: ...operly at your nearest recycling centre Only dispose of batteries when they are flat 8 Technical Data Min max operating pressure 0 bar 12 bar Flow medium Clean fresh water Max water temperature 40 C N...

Page 13: ...the purchaser or a non authorised third party have attempted to repair the unit Faults which occur as a result of incorrectly installed or leaking batteries are not covered by the guarantee This manuf...

Page 14: ...er f r kompletteringsdelar och tillbeh r H Term kfelel ss g Nyomat kosan utalunk arra hogy a term kfelel ss gi t rv ny rtelm ben nem felel nk a k sz l keink ltal okozott k rok rt amennyiben nem eredet...

Page 15: ...an v rt tillst nd H EU azonoss gi nyilatkozat Alul rott GARDENA Manufacturing GmbH Hans Lorenser Str 40 D 89079 Ulm igazolja hogy az al bb felsorolt ltalunk forgalomba hozott term kek megfelelnek az E...

Page 16: ...0 Ozna en p stroje Zavla ovac hodiny Typ v r EU directives Year of CE marking EU direktiv 2004 108 EC CE M rknings r EU ir nyelvek CE jelz s bevezet si ve 2004 Sm rnice ES 93 68 EC Rok um st n zna ky...

Page 17: ...m Costa Rica Compania Exim Euroiberoamericana S A Los Colegios Moravia 200 metros al Sur del Colegio Saint Francis San Jos Phone 506 297 68 83 exim_euro racsa co cr Croatia KLIS d o o Stanciceva 79 10...

Page 18: ...ctor 1 Bucure ti RO 013603 Phone 40 21 352 76 03 Russia 123007 32 7 495 540 99 57 info gardena rus ru Singapore Hy Ray PRIVATE LIMITED 40 Jalan Pemimpin 02 08 Tat Ann Building Singapore 577185 Phone 6...

Reviews: