v

 Position the pump at a safe distance (min. 2 m) from the water.

The pump must be installed in a location with low air humidity and suffi-

cient ventilation in the area of the ventilation slots. It must be at a distance 

of at least 5 cm from the walls. Dirt (e. g. sand or soil) must not be sucked 

in through the ventilation slots.

The plastic connection pieces on the intake and delivery sides may 

only be tightened by hand.

Fixed installation of the pump [ Fig. A1 ]:

A mounting plate 

(12)

 e. g. wooden plate (not included) prevents the pres-

sure tank unit from slipping.

v

 The Pressure Tank Unit can be screwed with all 4 feet 

(11)

 onto a solid 

surface 

(12)

 (We recommend the use of inbus screws).

Install the pressure tank unit so that there is room to place a suitably sized 

drainage tray under the drain screw 

(9)

 to allow the unit or system to be 

drained.
If possible, install the pump higher than the surface of the water to be 

pumped. If this is not possible, install a vacuum-resistant valve between 

the pump and the suction hose.
For permanent indoor installations for domestic water supply, the Pressure 

Tank Unit should not be connected to the domestic water pipework with 

rigid pipes but with flexible tubing, to reduce noise and to avoid damage to 

the pump caused by pressure blows.
If the system is being installed permanently, please fit suitable valves on 

both the intake and delivery sides. This is important e. g. for maintenance 

and cleaning work or if the system is being shut down.

To connect the hose to the suction side [ Fig. A2 ]:

Don’t use any hose quick connection system fittings on the suction side!

v

 A vacuum-resistant suction hose must be used, e. g. 

GARDENA 

 Suction  Unit,  Art. 1411

 or 

GARDENA Bore Hole Suction Hose  

Art. 1729

.

A suction hose with backflow preventor must be used so that  

the suction hose does not drain automatically when the pump  

is switched off.

1. Screw the non-return valve 

(2)

 into the pump connection 

(1)

 with the

O-ring 

ß

o

 in the direction of the pump up to the stop 

(a)

 until the stop 

(a)

touches the pump connection 

(1)

.

2. Connect the vacuum-resistant suction hose 

(3)

 airtight to the pump

non-return valve 

(2)

.

3. For suction heights exceeding 4 m: Also secure the suction hose 

(3)

(e. g. by fastening it to a wooden post).

This relieves the pump of the weight of the suction hose.

To connect the hose to the pressure side [ Fig. A3 ]:

The pump connection 

(4)

 is equipped with a 33.3 mm (G 1") internal 

thread.

Tip: If permanent pipes are installed, they must be laid at an 

ascending angle in order to allow the water to flow back into the 

pump on the pressure side.

Optimised use of the pump capacity is achieved by connecting  

19 mm (3/4") hoses with e. g. 

– GARDENA Pump Connection Set Art. 1752,

or by connecting 25 mm (1") hoses with

– GARDENA Quick Thread Coupling with male thread Art.  7115 / 

Quick Coupling Hose Connector Art. 7103.

1. Screw the pump connection piece 

(c)

 into the connector on the delivery

side 

(4)

.

2. Connect the pressure hose 

(5)

 to the pump connection piece 

(c)

.

When using other connectors, then use sealing tape 

(P)

 on the external 

thread of the fittings.
If more than one hose /accessory is connected simultaneously, we 

 recommend using the 

– GARDENA 2- or 4-Channel Water Distributor Art.  8193 / 8194, 

GARDENA Twin-Tap Connector Art. 940

which can be screwed directly onto the pump connection piece 

(c)

.

3. OPERATION

 DANGER! Risk of injury!
Injury when the product starts accidentally.

 Disconnect the product from the mains before you connect, 

adjust or transport the product.

To  pump  water  [ Fig.  O1 / O2 ]:

CAUTION! Dry-Running of the pump!

v

  Fill the pump with water up to the overflow (approx. 2 to 3 l) 

before each start-up.

1. Check the pressure in the storage tank (see 4. MAINTENANCE).
2. Unscrew the screw fitting 

(6)

 of the filler neck 

(7)

 by hand.

3. Fill the pump via the filler neck 

(7)

 to overflowing with

approx. 2 to 3 l of water.

4. Tighten the screw fitting 

(6)

 of the filler neck 

(7)

 by hand

(do not use pliers).

5. Open any shut-off valves in the delivery line (accessories,

water stop, etc.).

6. Drain remaining water in pressure hose 

(5)

 so that air can escape

during the suction process.

7. Connect the pump to the mains.
8. Lift and hold the delivery hose 

(5)

 at least 1 m vertically above the pump,

push the On / Off switch 

(8)

 and wait until the pump has primed.

v

 

If the pump does not deliver water after approx. 5 minutes, 

switch off the pump (press On / Off switch 

(8)

)  

(see 6. TROUBLESHOOTING).

Once the maximum pressure is reached the pump will switch off automati-

cally. When the pressure falls below the minimum value due to water being 

drawn off, the pump will switch on again automatically.
The specified maximum self-priming suction height of 7 m is reached  

only if the pump is filled via the filler neck up to the overflow and if, while 

doing so and during the self-priming, the delivery hose 

(5)

 is held up suf-

ficiently high to prevent any water escaping from the pump via the delivery 

hose 

(5)

.

4. MAINTENANCE

 DANGER! Risk of injury!
Injury when the product starts accidentally.

 Disconnect the product from the mains before you maintain  

the product.

To flush the pump:

After pumping chlorinated water, the pump must be flushed.
1. Pump lukewarm water (max. 35 °C), possibly adding a mild cleaning

agent (e. g. detergent) until the pumped water runs clear.

2. Remove residuals according to the waste disposal laws applicable in

your area.

To check the pressure in the storage tank [ Fig. M1 ]:

Check the pressure in the reservoir tank regularly.

The pressure in the storage tank must be approx. 1.5 bar. An air pump /  

tyre inflator with pressure indicator (manometer) is required to refill the air.
1. Unscrew the protective cover 

(13)

.

2. Open all the tapping points.

The pressure side is depressurised.

3. Place the air pump / tyre inflator on the tank valve 

(14)

 and refill with

air until the pressure display on the air pump / tyre inflator shows

approx. 1.5 bar.

4. Screw the protective cover 

(13)

 close again.

5. STORAGE

To put into storage [ Fig. S1 ]:

The pump is not frost-proof!

The product must be stored away from children. 

1. Disconnect the pump from the mains.
2. If applicable, close all the shut-off devices on the intake side.
3. Open all the tapping points.

The pressure side is depressurised.

EN

9

Summary of Contents for PTU 3700/4

Page 1: ...EN Operator s manual Pressure Tank Unit PTU 3700 4 Art 9023 EN...

Page 2: ...dnie z niemieck ustaw o odpowiedzialno ci za produkt niniejszym wyra nie o wiadczamy e nie ponosimy adnej odpowiedzialno ci za szkody poniesione na skutek u ytkowania naszych produkt w w przypadku gdy...

Page 3: ...A1 q w 9 A2 3 o 1 2 A3 5 x 4 N O1 6 5 7 O2 min 1 m 5 8 M1 r e S1 6 5 7 9 T1 7 0 T2 t z 3...

Page 4: ...structions This product may be used under supervision or if instruction regarding the safe use of the product has been provided and the resulting dangers have been under stood by children aged 8 and a...

Page 5: ...ne needles etc can cause damage to the pump v Do not pump dirty water IMPORTANT Read the operator s manual carefully before use and keep for future reference Symbols on the product Read operator s man...

Page 6: ...n using other connectors then use sealing tape P on the external thread of the fittings If more than one hose accessory is connected simultaneously we recommend using the GARDENA 2 or 4 Channel Water...

Page 7: ...Observe the max media temperature 35 C No power supply to the pump v Check fuses and electrical plug connections Problem Possible Cause Remedy Pump does not start or stops suddenly during operation R...

Page 8: ...its intended purpose as per the recommendations in the operating instructions Neither the purchaser nor a third party has attempted to open or repair the product Only Original GARDENA replacement part...