background image

11

GB

10

GB

The additional filter can be installed as a pond edge controller for
adjusting water features and cleaning the filter housing from the
edge of the pond. Water is only drawn in via the additional filter.
You can connect the following hoses to the hose connection:

3 /4

and 1

for FP 750 E / FP 1000 E / FP 1400 E / FP 1800 E /

FP 2500 E 

1 1/4

and 1 1/2

for FP 4000 E / FP 5000 E / FP 7500 E

For best results use a hose with the largest possible diameter.

1. Remove the cap 

3

from the pump.

2. Press in snap fastenings 

6

and 

open up the filter housing 

5

.

3. Push the hose connection 

7

on to the pump.

4. Close filter housing 

5

.

5. Insert hose connection 

8

in 

to one filter shell 

4

and snap 

into the second filter shell 

4

.

6. Press sealing cover 

3

on to 

the pond edge control 

4

.

7. Connect water feature pump 

and pond edge control to a 
hose.

4. Initial Operation 

1. Place water feature pump on a firm base in such a way that the

filter housing 

5

is completely covered by water.

2. Pull telescopic pipe 

9

out to the desired length.

3. Netzstecker in eine Wechselstromsteckdose einstecken.

Warning: Pump will start immediately.

4. Set the quantity of water required for the water feature using the

regulator 

0

.

5. Water bell : Screw insert into the water feature until the water

feature has produced the shape required.

TIP : Install the pond edge controller on a bed of gravel to
improve the water intake. The regulating valve

0

must be fully

open when using the pond edge controller.

1. Fill hose with water to remove any cushions of air in the hose.

2. Secure the pond edge controller at the edge of the pond (using

rocks, for example).
The pond edge control must be completely covered with water.

3. Set the quantity of water required for the water feature with the

regulator 

A

.

Switch on water 
feature pump :

Start pond edge control :

VARIANT 2 : Mount the pond
edge controller :

are people in the water. Swimming pools and
garden ponds should be designed according
to international and national design regulati-
ons.

v

Please consult a professional electrician.

For Austria :
Pumps for use on swimming pools and on
ponds may only be operated via an isolating
transformer.

v

Please consult a professional electrician.

For Switzerland :
In Switzerland mobile appliances which are
used outdoors, must be connected via a resi-
dual-current device.

Note :
Do not allow the pump to run without water
because dry-running leads to an undesira-
ble build up of heat.

Before operating the pump, look to see if there
is any damage of the pump (esp. regarding
power cable and plug). The connection cable
of the pump cannot be replaced. If the cable is
damaged the pump must be scrapped.

Do not use the power cable to carry the pump
or to pull the plug out of the socket. Protect
the power cable from heat, oil and sharp
edges.

The temperature of the liquid used must not
be below 4 °C or above 35 °C.

Sand and other abrasive substances in the
liquid cause increased wear and reduce the
output of the pump.

Please observe the local noise prevention
regulations.

All  pumps 

(a  cascade

art. 7650

(b  Waterbell

- 7654

(c  jets of

water

art. 7655 - 7657 

(d  foaming -

spring 

3. Assembly 

To provide a firmer mounting, the filter housing can be attached to
a solid base (e.g. paving stone).

1. Screw nozzle pipe

1

on to the pump with the ball and socket

joint.

2. Screw the water feature insert you require  (a (b (c (d on

the nozzle pipe 

1

.

2

Holder for GARDENA underwater light art 7951 

The additional filter can be fitted on the filter housing to extend the
maintenance interval and to give the water feature a longer life.

1. Remove the cap 

3

from the pump.

2. Fit both filter shells 

4

on the filter housing 

5

and clip into

place.

3. Press sealing cover 

3

on to the additional filter 

4

.

You can install additional filters 

to increase the filter surface.

Additional filters are available from GARDENA Service.

Fit the pump :

VARIANT 1 : Mount the addi-
tional filter on the pump:

5

3

4

2

1

0

A

9

5

0

9

5

4

3

8

7

7

3

5

6

 

 

 

Summary of Contents for FP 750 E

Page 1: ...ng Wasserspielpumpen Set GB Operating Instructions Fountain Pump Set F Mode d emploi Pompe pour jets d eau NL Gebruiksaanwijzing Waterspelpomp set S Bruksanvisning Fontän Pump Set I Istruzioni per l uso Pompa per giochi d acqua E Manual de instrucciones Bomba para juegos de agua P Instruções de manejo Bomba para fontes DK Brugsanvisning Springvandspumpesæt D GB F NL S I E P DK ...

Page 2: ...re not designed for operating watering tools and systems The pumps may be used indoors as well as outdoors GARDENA Fountain Pumps have not been designed for con stant use in the industrial sector Corrosive easily combustible aggressive or explosive substances e g petrol petroleum nitro thinner as well as salt water or food drinking water must not be pumped Intended Use Please note 2 For Your Safet...

Page 3: ...dges The temperature of the liquid used must not be below 4 C or above 35 C Sand and other abrasive substances in the liquid cause increased wear and reduce the output of the pump Please observe the local noise prevention regulations All pumps a cascade art 7650 b Waterbell 7654 c jets of water art 7655 7657 d foaming spring 3 Assembly To provide a firmer mounting the filter housing can be attache...

Page 4: ... Operation 1 Place water feature pump on a firm base in such a way that the filter housing 5 is completely covered by water 2 Pull telescopic pipe 9 out to the desired length 3 Netzstecker in eine Wechselstromsteckdose einstecken Warning Pump will start immediately 4 Set the quantity of water required for the water feature using the regulator 0 5 Water bell Screw insert into the water feature unti...

Page 5: ...2 Unscrew water feature insert and remove from nozzle pipe 3 Clean nozzle pipe and water feature insert in clean water 1 Take water feature pump out of the water 2 Unlock snap fastenings 6 and open up the filter housing 5 3 Clean filter housing 5 with a jet of water 4 Hook the halves of the filter housing into each other and close Do not use any hard objects or powerful detergents for cleaning the...

Page 6: ...rating Mains plug not plugged in V Plug in mains plug Impeller unit is blocked V Clean pump Regulating valve at pump or V Open the appropriate pond edge controller is closed regulating valve FP 1800 E FP 2500 E Thermal overload switch has 1 Unplug the mains plug FP 7500 E been triggered and allow the pump to cool pump has run dry 2 Plug the mains plug back in after approx 2 minutes FP 750 E FP 100...

Page 7: ... room GARDENA Spiral Pond Hoses For connecting the pond edge controller art 7896 art 7898 GARDENA Water Features For designing your own pond and art 7814 art 7823 water features GARDENA Telescopic Tubes For extending the nozzle tube art 7884 art 7885 9 Technical Data Type FP 750E FP 1000E FP 1400E FP 1800E FP 2500E FP 4000E FP 5000E FP 7500E Art No 7650 7651 7652 7653 7654 7655 7656 7657 Rated pow...

Page 8: ...s of the operating in structions Neither the purchaser or a non authorised third party have attempted to repair the unit The feed impeller is a wearing part and is not covered by the warranty This manufacturer s guarantee does not affect the user s existing warranty claims against the dealer seller If you have any problems with your Fountain Pump Set please contact our Service or return the defect...