15
G
14
G
Wintering / Storage :
7. Putting out of Operation
1. Before frosts commence, remove the Filter Set from the pond,
take the hose off the pump and empty the filter completely.
2. Clean the Filter Set.
3. Store filter and pump in a frost-free place.
4. Store the pump in a container filled with water so that the
pump does not dry out.
Ensure that the mains plug is not in the water.
Store out of reach of children.
8. Technical Data
Art. No.
7919
Rated power
14 W
Flow
900 l / h
Max. delivery head
1.5 m
Max. submersion depth
1.0 m
Power cable
10 m H05 RNF
Fitting
G 1/ 2
Max. media temperature
35 °C
Mains voltage / Frequency
230 V / 50 Hz
Noise level L
WA
1)
48 dB (A)
1) Measuring method according to EN 60335 -1
9. Service
GARDENA guarantees this product for 2 years (from date of
purchase). This guarantee covers all serious defects of the unit
that can be proved to be material or manufacturing faults. Under
warranty we will either replace the unit or repair it free of charge
if the following conditions apply:
•
The unit must have been handled properly and in keeping
with the requirements of the operating instructions.
•
Neither the purchaser or a non-authorised third party have
attempted to repair the unit.
The impeller unit and the filter pellets are wearing parts and are
not covered by the guarantee.
This manufacturer’s guarantee does not affect the user’s existing
warranty claims against the dealer / seller.
If you have any problems with your pump, please contact our
Customer Service or return the defective unit together with
a short description of the problem directly to one of the
GARDENA Service Centres listed on the back of this leaflet.
Warranty
Cleaning the pump filter housing :
The water intake slots on the water feature pump must be free
from dirt.
1. Unplug the pump from the mains.
2. Remove the pump from the pond.
3. Unscrew threaded sleeve
F
and connection piece
2
.
4. Open up the pump filter housing
G
and spray clean with
a jet of water.
5. Clean the water intake slots of the filter housing
G
with
a brush.
Note :
Do not use any hard objects or powerful detergents for cleaning
the set !
Remove dirt deposits in the pump :
1. Unplug the pump from the mains.
2. Remove the pump from the pond.
3. Unscrew threaded sleeve
F
and connection piece
2
.
4. Open up pump filter housing
G
and remove the pump.
5. Open the snap hook
b
and take the pump cover
H
off the
motor housing
J
.
6. Draw the impeller unit
I
out of the motor housing
J
.
7. Remove any dirt deposits from pump components.
8. Replace the impeller unit
I
in the motor housing
J
.
9. Press the pump cover
H
into the motor housing
J
until the
connection is heard to snap into place.
6. Trouble-Shooting
Fault Possible
Cause
Remedy
The water is not clear.
The pond is extremely dirty
1. Check nitrate concentration
and rich in nutrients.
(e. g. with the GARDENA
Pond Test Set, Art. No.
7920)
2. If necessary, change the
water and clean the pond.
Filter pellets dirty.
v
Clean filter and filter pellets.
Too many fish and creatures
v
Add up the estimated length
in the pond.
of the fish.
There should only be “80 cm
fish” per m
3
water in the pond.
Pump does not work.
Connections are faulty.
v
Check connections.
Impeller unit blocked.
v
Remove dirt deposits in the
pump (see 5. Maintenance).
If any other faults arise, please contact GARDENA Service.
Cleaning the pump :
2
F
G
J
H
b
I
www.devicemanuals.eu