background image

4. OPERATION

4.1. Basic Programming
Date and Time (Time Key)

You can end the programming mode at any time  

by pressing the Time key.

Setting the date and time:

You must set the date and time before you can 

set the watering programs. The day of the week is 

selected automatically using the date. When the 

Time key is pressed, all the valves are closed as 

a precaution.

1.  [ Fig.  O1 ]:  Plug in the power supply unit – or – 

press the Time key. 

YEAR  

YEAR  

and date-year flash in the display.

2. [ Fig.  O1 ]: Select the date-year using the  

-

 keys (e. g. 

2010

2010

) and confirm by pressing  

the OK key. 

MONTH  

MONTH  

and date-month flash.

3. [ Fig.  O2 ]:  Select the date-month using the  

-

 keys (e. g. 

05

05

) and confirm by pressing the 

OK key. 

DAY

DAY

 and date-day flash.

4. [ Fig.  O3 ]:  Select the date-day using the  

-

 keys (e. g. 

23

23

) and confirm by pressing  

the OK key. 

TIME

TIME

 and time-hours flash.

5. [ Fig.  O4 ]:  Select the time-hours using the  

-

 keys (e. g. 

12  

12  

hours) and confirm by pressing 

the OK key. 

TIME

TIME

 and time-minutes flash.

6. [ Fig.  O5 ]:  Select the time-minutes using the 

-

 keys (e. g. 

30  

30  

minutes) and confirm by 

pressing the OK key.

[ Fig.  O6 ]:  The date and time have been set and 

the main level is displayed.

Watering Programs (Channel Key)

Prerequisite: The date and time have been set.

To give you a better overview, we recommend that 

before starting to enter the watering data you enter 

the data for your valves into the watering plan in the 

appendix of these operating instructions.
You can save 3 watering programs for each channel 

(a maximum of 3 programs x 4 (Art. 1283) /  

6 (Art. 1284) channels = 12 (Art. 1283) /  

18 (Art. 1284) programs).

Ending the programming mode prematurely:
You can exit the programming mode prematurely at 

any time.

v  

Press the Channel key twice. 

The main level is displayed.

Setting the watering programs:

PLEASE NOTE!  

If two programs overlap on one channel, this 

results in the total watering duration being 

less than planned. If two programs overlap 

on different channels, the water pressure 

may drop to an extent such that watering is 

inadequate or the pop­up sprinklers fail to 

extend.

v  

Make sure that the watering times of the 

programs do not overlap.

Selecting the channel and program memory 

location:
1.  [ Fig.  O7 ]:  Press the Channel key. 

SELECT  CHANNEL

SELECT  CHANNEL

 and the channel flash.

You can end the programming mode at any time by 

pressing the Channel key.
2. [ Fig.  O8 ]:  Select the channel using the 

-

 

keys (e. g. channel 2) and confirm by pressing 

the OK key. 

 Channel appears on the display (e. g. 2) and 

Select Program and the program memory 

location flash.

3. [ Fig.  O9 ]:  Select the program memory location 

using the 

-

 keys (e. g. program memory 

 location  3) and confirm by pressing the OK key. 

Start Time and the hours for the watering start 

time flash.

Setting the watering start time:
4. [ Fig.  O10 ]:  Select the hours for the watering 

start time using the 

-

 keys (e. g. 

16

16

) and 

 confirm by pressing the OK key. 

Start Time Time and the minutes for the water-

ing start time flash.

5.  [ Fig.  O11 ]:  Select the minutes for the watering 

start time using the 

-

▼ 

keys  (e. g. 

30

30

) and con-

firm by pressing the OK key. 

Run Time and the hours for watering duration 

flash.

Setting the watering duration: 

(This always corresponds to 100 % Run Time)
6.  [ Fig.  O12 ]: Select the hours for watering dura-

tion using the 

-

 keys (e. g. 

1  1  

hour) and confirm 

by pressing the OK key. 

Run Time and the minutes for watering duration 

flash.

16

EN

Summary of Contents for 4030

Page 1: ...4030 Art 1283 6030 Art 1284 EN Operator s manual Watering Controller EN...

Page 2: ...1 I2 MASTER VALVE MASTER SENSOR CHANNELS 5 3 4 M F1 I3 MASTER VALVE MASTER SENSOR CHANNELS F2 W Z Q U R E T I1 1 2 I4 6 7 6 6 O1 O2 O3 O4 O5 O6 O7 O8 2...

Page 3: ...O9 O10 O11 O12 O13 O14 O15 O16 O17 O18 O19 O20 O21 O22 O23 O24 O25 O26 O27 O28 O29 O30 3...

Page 4: ...ions provid ed by GARDENA is a prerequisite for proper use of the Watering Controller Please note The Watering Controller must be used only for controlling commercially available 24 V AC valves The el...

Page 5: ...f the particular channel is being programmed If a channel is currently open the frame of the opened watering channel flashes T Display of watering times Indicates the start time and duration of wateri...

Page 6: ...cable of the valve V2 to a cable terminal C of the valve box Other valves can be connected similarly to V1 and V2 Connecting the Watering Controller to the Valve Box Connect a cable terminal C of the...

Page 7: ...rams Ending the programming mode prematurely You can exit the programming mode prematurely at any time v Press the Channel key twice The main level is displayed Setting the watering programs PLEASE NO...

Page 8: ...u only need to change the specific values of the watering program you want to change You can transfer all other values from Setting the watering programs by pressing the OK key 4 2 Special Functions B...

Page 9: ...grams 1 Fig O24 Press the Run Time key RUN TIME RUN TIME and the percentage watering duration flash 2 Fig O25 Select the figure for the percentage watering duration using the keys e g RUN RUN TIME 60...

Page 10: ...pply unit into a mains socket OVERLOAD OVERLOAD is indicated on the display the programs are retained The power supply is overloaded because valves from other manufacturers have been used v Only so ma...

Page 11: ...al or manufac turing faults This war ranty is fulfilled by supplying a fully functional replacement product or by repair ing the faulty product sent to us free of charge we reserve the right to choose...

Page 12: ...nnel Prog START TIME START TIME RUN TIME RUN TIME 24h 2nd 3rd Odd Even Mo Tu We Th Fr Sa Su 1 2 3 Channel Prog START TIME START TIME RUN TIME RUN TIME 24h 2nd 3rd Odd Even Mo Tu We Th Fr Sa Su 1 2 3 C...

Page 13: ...os korjauksia ei ole tehnyt GARDENAn hyv ksy m huolto liike tai jos niiden syyn on muiden kuin alkuper isten GARDENA varaosien tai GARDENAn hyv ksymien varaosien k ytt IT Responsabilit del prodotto In...

Page 14: ...S 103 92 Tukholma Ruotsi valtuuttamana henkil n ett seuraava laite t ytt seuraavat laitteet t ytt v t meid n toimittamassa mallissa yhdenmukaistet tujen EU direktiivien EU turvallisuusm r ysten ja tuo...

Page 15: ...E Kennzeichnung Year of CE marking Ann e d apposition du marquage CE Installatiejaar van de CE aanduiding CE M rknings r CE M rknings r CE merkin kiinnitysvuosi Anno di applicazione della certificazio...

Page 16: ...County Durham DL5 6UP info gardena husqvarna co uk Italy Husqvarna Italia Spa Centro Direzionale Planum Via del Lavoro 2 Scala B 22036 ERBA CO Tel 39 031 4147700 assistenza italia it husqvarna com Ja...

Reviews: