For suction heights exceeding 4 m also secure the suction hose
5
(e. g. by fastening it to a wooden post) to relieve the pump of the
weight of the suction hose.
If very fine dirt is present in the pumping medium, we
recommend the use of a GARDENA Pump Preliminary Filter
Art. no. 1730 / 1731.
Connect hose to the
output side:
9
8
7
Note:
Use pressure-tight GARDENA hoses, 19 mm (3/4") in diameter,
in connection with the GARDENA Quick-Release Threaded
Connector with 33.3 mm (G1) internal thread, Art. no. 7109,
and the GARDENA Suction and High Pressure Connector,
Art. no. 7120, for 19 mm (3/4") hoses and a GARDENA Hose
Clip, Art. no. 7192. Under no circumstances use these hoses
on the suction side.
1.
Connect the delivery hose
7
with one of the three
connections
8
to the delivery side.
2. Unused pressure connections must be closed off with an
end cap
9
.
Tip: With fixed piping, only assign max. 2 connections
8
so that
the air can be bled off via the end cap
9
of the third connection.
4. Operation
Starting the Pressure Tank Unit:
q
Off
Man.
Auto
Start
0
9
e
8
q
Off
Man.
Auto
Start
DANGER! Electric shock!
v
Before filling the pump, unplug the equipment from
the mains.
Warning!
v
Fill the pump to the overflow (approx. 2 to 3 l) with water
each time before the pump is switched on.
1. Turn the rotary switch
q
to OFF.
2. Unscrew the cover
0
of the filter chamber by hand.
3. Open an end cap
9
on the delivery side to bleed off the air.
4. Open any valves in the delivery line (watering accessories, water
stop, etc.) and drain off any residual water in the delivery hose
so that the air can escape during filling and priming.
5. Slowly pour pumping medium (approx. 2 to 3 l) through the
filler neck
e
until water emerges from the open delivery side
connection
8
.
6. Screw the filter chamber cover
0
closed again, turning by hand
until it stops.
7. Close the end cap
9
on the delivery side which had been
opened to bleed off the air.
8. Insert the mains plug into a 230 V mains socket.
9. Turn the rotary switch
q
to START.The pump will start
immediately!
Once priming has taken place, the rotary switch switches auto-
matically to AUTO and the dry-running safety is activated. Once
the maximum pressure is reached the pump will switch off auto-
matically. When the pressure falls below the minimum value due to
water being drawn off, the pump will switch on again automatically.
15
GB
1754-20.960.01.indd 15
1754-20.960.01.indd 15
05.07.13 11:08
05.07.13 11:08