background image

The power cable of the Submersible Pressure Pump must be connected  

to a socket which is positioned at a height of 1.10m  (measured from ground).

Take care that the power cable leads downwards.
Data indicated on the type plate must match technical data of the mains supply.

v

 Consult your qualified electrician.

v

  Take care that the electrical connections are made within dry area, protected 

from flooding.

v

 Keep mains plug dry.

Protect plug and power cable from heat, oil and sharp edges.
The power cable must not be used for mounting or relocating the pump. For sub-

merging or  lifting / securing the pump, please use the  fastening rope.

In Austria
In Austria the electrical connection must satisfy the  ÖVE-EM 42, T2 (2000) / 1979 

§ 22 to § 2022.1. This requires that pumps used for swimming pools and garden 

ponds may only be powered through an isolating trans former.

v

  Please ask your electrician for his advice.

In Switzerland
In Switzerland mobile appliances which are used outdoors, must be connected 

via a residual-current device.

Notes on use
When connecting the pump to the water supply system, the country-specific 

sanitary regulations must be observed to prevent water not of drinking water 

quality being drawn back in.

v

  If necessary, contact your sanitary expert.

Sand and other abrasive substances cause increased wear and reduce the 

pump’s output.
During operation, the pump must always be submersed in the water up to the 

minimum submersion depth (see 6. TECHNICAL DATA) 
Do not allow the pump to run for more than 10 minutes against the closed  

pressure side (e. g. closed valve, closed dispenser etc.).
Leaking lubricants can contaminate the pumped liquid.
DANGER! This product makes an electromagnetic field while it operates. This 

field may under some conditions interfere with active or passive medical implants. 

To decrease the risk of conditions that can possibly injure or kill, we recommend 

persons with medical implants to speak with their physician and the medical 

implant manufacturer before you operate the product.
DANGER! Small parts can be easily swallowed. There is also a risk that the poly-

bag can suffocate toddlers. Keep toddlers away when you assemble the product.

2. INITIAL OPERATION

Connect hose via the GARDENA Connection System [ Fig. I1 ]:

19 mm (3/4")- / 16 mm (5/8") and 13 mm (1/2") hoses can be  connected 

via the GARDENA Connection System.

Hose diameter

Pump connection

13 mm (1/2")

Pump Connection Set

Art. 1750

16 mm (5/8")

GARDENA Tap Connector

GARDENA Hose Connector

Art. 18202 

Art. 18216

19 mm (3/4")

GARDENA Pump Connection Set

Art. 1752

The pump connection component 

1

 is already pre-installed by the manu-

facturer together with the check valve 

ß

v

 .

v

  Connect hose via the relevant GARDENA Connection System.

Backflow preventer 

ß

v

 [ Fig.  I1 ]:

The backflow preventer 

ß

v

 prevents the hose from running empty after the 

pump has been turned off or taken out of operation.
With a parallel connection of more than one hose or connected devices, 

the GARDENA  2­ / 4­Way  Valve  (Art.  8193 / 8194) can be used, which  

is screwed straight onto the pump connection piece 

1

.

Pump installation [ Fig. I2 ]:

The pump must always be submerged in the fountain or water reservoir 

with the fastening rope 

3

 provided. For the pump to be primed,  

the pump must be submerged to the minimum submersion depth 

ß

t

 

(see 6. TECHNICAL DATA) So that the filter does not become dirty, the 

pump should be fixed at least 30cm above the ground.

1. Attach the fastening rope 

3

 to the handle 

4

.

2.  Submerge pump in the fountain or water reservoir via the  fastening 

rope 

3

.

3. Secure fastening rope 

3

.

4. With deep fountains or shafts (from approx. 5m), route the  connection 

cable 

5

 along the fastening rope 

3

 with clips.

Thermal protection switch:
In the event of an overload, the pump is switched off by the  built-in  

thermal motor protection. After sufficient cooling of the motor, the pump  

is operational again.

3. OPERATION

Automatic operation [ Fig. O1 ]:

The float switch 

6

 turns the pump on automatically when the water level 

exceeds the cut-in height and the water is pumped out. The float switch 

6

 turns the pump off again as soon as the water level falls below the 

cut-out height.

v

  During automatic operation, ensure that the float switch 

6

 can 

move freely.

Adjusting the Cut­in and Cut­out Height:
The cable length between the float switch 

6

 and the float switch lock 

7

 

must always be at least 10 cm.
1. Press the cable of the float switch 

6

 into an opening in the  

float switch lock 

7

Do not select a cable length that is too long or short to ensure that the 

float switch can turn on and off properly.

2. Plug the mains plug of the connection cable 

5

 into a mains socket. 

The pump is now ready for operation.

•  The higher the opening of the float switch lock 

7

, the higher  

the cut-in and cut-out height.

•  The shorter the length of cable between the float switch 

 

and the float switch lock 

7

, the lower the cut-in height and the higher 

the cut-out height.

Manual operation:
The pump remains in constant operation when the float switch is attached 

facing upwards so that the cable is pointing downwards.

v

  Attach the float switch 

6

 to the top so that the cable points downward.

The residual water height of approx. 25 mm is only reached  during 

manual operation since the float switch turns off the pump during auto-

matic operation before this water level is reached.

4. STORAGE

To put into storage:

The product must be stored away from children.

 Store the pump away from frost before the first frost sets in.

Disposal: 

(in accordance with RL2012/19/EC)

The product must not be disposed of to normal household waste. It 

must be disposed of in line with local environmental regulations.

IMPORTANT!
Dispose of the product through or via your municipal recycling collection 

centre.

5. TROUBLESHOOTING

  

DANGER! Electric shock!

 

There is a risk of injury from electric shocks.

v  

Before maintenance, disconnect the submersible pressure 

pump from the mains.

Problem

Possible Cause

Remedy

The pump does not  

deliver any water

Air cannot escape as the  

pressure line is closed.

v

    

Open pressure line  

(e. g. bent pressure hose).

Air cushion in suction foot.

v

    

Unplug mains cable and  

plug in again.

When starting the pump,  

water height falls below the  

min. water level.

v

  

Submerge pump deeper  

(see 6. TECHNICAL DATA /  

Minimum submersion depth 

on commissioning).

7

EN

Summary of Contents for 1461

Page 1: ...n PT Manual de instru es Bomba submers vel de press o PL Instrukcja obs ugi Pompa zanurzeniowo ci nieniowa HU Haszn lati utas t s Mer l nyom szivatty CS N vod k obsluze Ponorn tlakov erpadlo SK N vod...

Page 2: ...ie z niemieck ustaw o odpowiedzialno ci za produkt niniejszym wyra nie o wiadczamy e nie ponosimy adnej odpowiedzialno ci za szkody poniesione na skutek u ytkowania naszych produkt w w przypadku gdy n...

Page 3: ...3 I1 1 v I2 t 3 5 6 4 O1 6 5 7...

Page 4: ...Salt water contaminated water corrosive easily flammable or explosive substances for example gasoline petroleum cellulose thinner oil heating oil and foodstuffs may not be conveyed The water temperat...

Page 5: ...nection piece 1 Pump installation Fig I2 The pump must always be submerged in the fountain or water reservoir with the fastening rope 3 provided For the pump to be primed the pump must be submerged to...

Page 6: ...via the GARDENA Connection System Art 18202 Art 18216 GARDENA Pump Connection Set For 19 mm 3 4 hoses via the GARDENA Connection System Art 1752 8 SERVICE WARRANTY Service Please contact the address...

Page 7: ...stikk Curva di rendimento Curva caracter stica de la bomba Caracter sticas de performance Charakterystyka pompy Szivatty jellegg rbe Charakteristika erpadla Charakteristiky erpadla Karakteristika rpal...

Page 8: ...su EL GARDENA Germany AB PO Box 7454 S 103 92 Stockholm SL Izjava ES o skladnosti Spodaj podpisana GARDENA Germany AB PO Box 7454 S 103 92 Stockholm vedska s to izjavo potrjuje da je bila spodaj naved...

Page 9: ...rdena husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development K...

Reviews: