- 18 -
III.
Technical Specifications
Model
GP00 GP01 GP02 GP03 GP04 GP05 GP06
GP07
Performance Condition: Air 26
℃
, Water 26
℃
Heating capacity
KW
3.6 5 7 10 13 17 25
26
C.O.P.
5.2
5.3
6.3
6.2
6.3
6.2
6.4
6.5
Performance Condition: Air 15
℃
, Water 26
℃
Heating capacity
KW
2.7
3.7 5 7 9 12 16.5 17
C.O.P.
4.1
4.3
4.5
4.4
4.5
4.5
4.5
4.7
Advised Water Flux
m³/h
2.5 3 3-4 4-6 5-7
6.5-8.5 8-10 8-10
Power supply
220-240V/1Ph/50Hz
380-415V/3
Ph/50Hz
Rated power Kw 0.66
0.86
1.11
1.59
2
2.67
3.67
3.62
Rated current A
3
3.9
5.0
7.2
9.1
12.1
16.7
5.5
Water pipe in-out
spec
mm
50
Water pipe in-out
spec(For UK) mm
48
Net weight / Gross
weight Kg
31/36 35/40 45/50 53/56 66/70 85/93 127/137 127/137
Notice:
1-
This Heat Pump can work well between 0
℃~
+43
℃
air temperature;
efficiency will not be guaranteed out of this range. Please take into
consideration that the pool heater performances may vary under different
conditions. Consult your Pool specialist.
2-
We reserve the right to make improvements periodically without further
notice. For details please refer to the cover-plate on the Heat Pump.