background image

13

CONTROL PANEL OPERATION

DIAGNOSTIC  LCD MESSAGE

Message Meaning

Action Required

No message on display.

Power has been cut off to the spa.

The control panel will be disabled until power 

returns. Spa settings will be preserved until next 

power up.

HL

The system has shut the heater off 

because the temperature at the heater 

has reached 48°C (119°F). Do not enter 

the water!

DO NOT ENTER THE WATER. Remove the spa 

cover and allow the water to cool down, then shut 

power off and power your spa up again to reset the 

system.

If spa does not reset, shut off the power to the spa 

and call Customer Service.

AOH

Temperature inside the equipment 

compartment is too high 90°C (194°F), 

causing the internal temperature in 

the control system to increase above 

normal limits.

Open equipment compartment and wait until error 

clears.

 Prr

A problem is detected with the 

temperature probe. 

Call Customer Service.

  OH

The water temperature in the spa has 

reached 42°C (108°F). Do not enter the 

water!  

Remove the spa cover and allow the water to cool 

down to a lower temperature. Call your Dealer or 

service supplier if problem persists.

Hr

An internal hardware error has been 

detected.

Call Customer Service.

FLO

No water flow is detected by the control 

system but flow is expected.

Make sure that the jet pump is running and water 

is flowing; check and clean filters; make sure water 

valves are open; make sure spa has a proper 

water level. If problem persists, call Customer 

Service. 

  

WARNING! SHOCK HAZARD! NO USER SERVICEABLE PARTS.

Do not attempt service of the control box. Contact Customer Service for assistance. Follow all owner manual 

power connection instructions. Installation must be performed by a licensed electrician and all grounding 

connections must be properly installed.

SETTING ECONOMY MODE

In Economy mode you are able to lower the set temperature 

of the spa by 20º F (11º C) during a certain period of day 

which is adjustable as well as the length of time. One of the 

main reasons you might want to enable this feature at night 

is to limit the amount of times the spa will automatically turn 

on either because of calling for heat or sampling the water for 

temperature. 

NOTE:

 If the Economy Mode set time is enabled during a filter 

cycle, the filter cycle will NOT come on during the enabled time.

To enable the economy mode:

1.  Press and hold 

Light

 button for 5 seconds until clock 

hour is displayed, press 

Light

 button several more times 

until EPx is displayed, x representing the state of the 

mode (0=disabled, 1=enabled)

2.  Press the 

Up +/Down -

 button to either enable or disable 

the economy mode.

3.  Press the 

Light

 button again to set the Economy Start 

time. The display will show ESxx where "xx" represents 

the hour at which the economy mode will become active. 

Press the 

Up +/Down -

 button to set the hour you want 

the mode to be enabled.  

A dot after the ES represents AM.

NOTE:

 The time may be set, however, if Economy is 

disable - 0, the Economy Mode feature will Not come on. 

4.  Press the 

Light

 button again to set the Economy 

Duration time. The display will show Edxx, "xx" representing 

how long (in hours) you want the economy mode to be ON. 

Use the 

Up/Down

 buttons to adjust the amount of hours. 

FAHRENHEIT/CELSIUS SETTING 

To change water temperature display to either Fahrenheit or 

Celsius, press and hold 

Light

 button for 5 seconds until clock 

hour is displayed, press 

Light

 button several more times until F 

or C is displayed. Press the 

Up/Down

 button to change. 

Summary of Contents for Garden-696L

Page 1: ...OWNER S MANUAL 50HZ...

Page 2: ...0 lbs 1 211 L 320 gal Garden 780 7 person 213 cm 84 213 cm 84 91 cm 36 376 kg 830 lbs 1 317 L 348 gal Garden 642L 6 person 213 cm 84 213 cm 84 91 cm 36 367 kg 810 lbs 1 208 L 319 gal Garden 742 7 pers...

Page 3: ...S 11 OPERATIONAL MODES GARDEN 642L GARDEN 742 GARDEN 334L MODELS ONLY 12 DIAGNOSTIC LCD MESSAGE 13 COMPONENT OPERATION SPACOMPONENT OPERATION 14 FILL UP AND START UP INSTRUCTIONS FILLING THE SPAWITH W...

Page 4: ...only to a grounded source Do not bury the power cord A buried power cord may result in death or serious personal injury due to electrocution if direct burial type cable is not used or if improper digg...

Page 5: ...ectrocution if the appliance should fall into the spa Install your spa in such a way that drainage is away from the electrical compartment and from all electrical components DO Be sure your spa is con...

Page 6: ...on for at least ten minutes after adding ANY spa water chemicals into the filter compartment Clean the filter cartridge monthly to remove debris and mineral buildup which may affect the performance of...

Page 7: ...ls and cleaners DON T Leave the spa exposed to the sun without water or the cover in place Exposure to direct sunlight can cause solar distress of the shell material Roll or slide the spa on its side...

Page 8: ...nstallations require adequate ventilation When the spa is in use considerable amounts of moisture are produced This moisture can damage walls and ceiling surfaces over time Special paint is available...

Page 9: ...o the spa area An architect can help to determine if more ventilation must be installed PLACING THE SPA CHECK THE DIMENSIONS OF YOUR SPA Compare the spa dimensions to the width of gates sidewalks and...

Page 10: ...panel slightly pull bottom of door away from spa then remove Equipment Compartment EQUIPMENT ACCESS PANEL Electrical Access Electrical Access Serial No LEFT SIDE OF SPA FOR HEAT PUMP ONLY Front side...

Page 11: ...e labeled and easily accessible to users 4 The electrical supply for the spa must include a suitable circuit breaker to open all ungrounded supply conductors to comply with your National local code Th...

Page 12: ...e electrical service using one 40 amp breaker with 3 wires The spa must be connected to a dedicated RCD circuit breaker that is not shared with any other equipment Do not use extension or plug type co...

Page 13: ...rrent spa temperature The heater indicator lights up when the heater is on It flashes when there is a request for more heat but the heater is not on Once set temperature is reached the indicator shuts...

Page 14: ...for 5 seconds until F1 is displayed 2 Press the Plus or Minus button to adjust the cycle time for F1 3 Press the Light button to store the F1 cycle and move to the F2 cycle 4 Press the Plus or Minus...

Page 15: ...ur 2 times per day spread out by 12 hours if the clock is not set and will start at 12 Filter cycles only run at low speed however the second pump will purge for a minute first during each filter cycl...

Page 16: ...nnection instructions Installation must be performed by a licensed electrician and all grounding connections must be properly installed SETTING ECONOMY MODE In Economy mode you are able to lower the s...

Page 17: ...FAC Aquaterra recommends that a chemical maintenance program based on recognized and documented industry standards still be followed when using an ozone purification system to assure water sanitation...

Page 18: ...tem and invalidate your warranty If your spa filter is sucking in air causing the pump to cavitate you need to add water 7 Check the filter installation and make sure the filter is not loose APPLYING...

Page 19: ...ty Up Increaser sodium bicarbonate or sodium hydrogen carbonate These products should be added in small amounts 1 tablespoon at a time After adding wait one half hour before re measuring Once the safe...

Page 20: ...button for 8 second to OFF 2 Pull out the basket and weir Carefully unscrew the filter cartridge and bring it out of the spa 3 Always clean the filter using a filter degreaser to remove mineral and oi...

Page 21: ...er and air dry IMPORTANT Do not let the polyester dry with a soap film on it before it can be rinsed clean 4 Scrub the cover s perimeter and side flaps Rinse clean with cold water 5 Rinse off the unde...

Page 22: ...nes and jets a It will be necessary to remove all water from the interior plumbing b Remove the floating weir basket and filter cartridge Clean the filter cartridge and store in a dry place Attach the...

Page 23: ...ed jet action 3 Make sure the water level is half way between top of spa and top of the gray filter ring 4 Check for dirty filter Clean if necessary 5 Make sure all jets are in the open position WATER...

Page 24: ...21 305314 24 A 9 23...

Reviews: