VISCOSITY

26

EZ

 VISCOSITY CUP #4

EFFLUX TIME - CENTISTOKES CONVERSION TABLE

©

10/95 

(Accurate for True Liquids Only) 

SECONDS 

0.0 

0.1 

0.2  0.3 

0.4 0.5 0.6 

0.7 0.8 0.9

VISCOSITY IN CENTISTOKES

>

>

10 

  65 

  67 

  69 

  71 

  73 

  75 

  77 

  79 

  81 

  83

11 

  85 

  87 

  88 

  90 

  92 

  94 

  96 

  98 

  99 

101

12 103 105 

107  108 110 

112 114 115 

117 119

13 121 122 

124  126 127 

129 131 133 

134 136

14 138 139 

141  143 144 

146 148 149 

151 152

15 154 156 

157  159 161 

162 164 165 

167 169

16 170 172 

173  175 176 

178 180 181 

183 184

17 186 187 

189  190 192 

194 195 197 

198 200

18 201 203 

204  206 207 

209 210 212 

213 215

19 217 218 

220  221 223 

224 226 227 

229 230

20 232 233 

235  236 238 

239 240 242 

243 245

21 246 248 

249  251 252 

254 255 257 

258 260

22 261 263 

264  266 267 

268 270 271 

273 274

23 276 277 

279  280 282 

283 284 286 

287 289

24 290 292 

293  295 296 

297 299 300 

302 303

25 305 306 

307  309 310 

312 313 315 

316 317

26 319 320 

322  323 325 

326 327 329 

330 332

27 333 335 

336  337 339 

340 342 343 

344 346

28 347 349 

350  351 353 

354 356 357 

359 360

29 361 363 

364  366 367 

368 370 371 

373 374

30 375 377 

378  380 381 

382 384 385 

387 388

31 389 391 

392  394 395 

396 398 399 

401 402

32 403 405 

406  407 409 

410 412 413 

414 406

33 417 419 

420  421 423 

424 426 427 

428 430

34 431 432 

434  435 437 

438 439 441 

442 443

35 445 446 

448  449 450 

452 453 455 

456 457

36 459 460 

461  463 464 

466 467 468 

470 471

37 472 474 

475  477 478 

479 481 482 

483 485

38 486 488 

489  490 492 

493 494 496 

497 499

39 500 501 

503  504 505 

507 508 509 

511 512

40 514 515 

516  518 519 

520 522 523 

525 526

41 527 529 

530  531 533 

534 535 537 

538 540

42 541 542 

544  545 546 

548 549 550 

552 553

43 555 556 

557  559 560 

561 563 564 

565 567

44 568 570 

571  572 574 

575 576 578 

579 580

45 582 583 

584  586 587 

589 590 591 

593 594

46 595 597 

598  599 601 

602 603 605 

606 608

47 609 610 

612  613 614 

616 617 618 

620 621

48 622 624 

625  627 628 

629 631 632 

633 635

49 636 637 

639  640 641 

643 644 645 

647 648

50 650 651 

652  654 655 

656 658 659 

660 662

51 663 664 

666  667 668 

670 671 673 

674 675

52 677 678 

679  681 682 

683 685 686 

687 689

53 690 691 

693  694 695 

697 698 700 

701 702

54 704 705 

706  708 709 

710 712 713 

714 716

55 717 718 

720  721 722 

724 725 726 

728 729

56 731 732 

733  735 736 

737 739 740 

741 743

57 744 745 

747  748 749 

751 752 753 

755 756

58 757 759 

760  762 763 

764 766 767 

768 770

59 771 772 

774  775 776 

778 779 780 

782 783

60 784 786 

787  788 790 

791 792 794 

795 796

Example: 45.9 Seconds = 594 Centistokes.        

©Copyright 1987 Paul N. Gardner Co.

 Paul N. Gardner • www.gardco.com • (954) 946-9454 

Summary of Contents for EZ ZAHN Dip Viscosity Cup Series

Page 1: ...Cup I S O Viscosity Cup Din Viscosity Cup Fisher Standard Cup Standard Ford Dip Viscosity Cup Mini Ford Dip Viscosity Cup Mini I S O Dip Viscosity Cup Mini Din Dip Viscosity Cup Fisher Dip Viscosity C...

Page 2: ...licable The EZ Cup is not matched by any other cup of its type either with respecttotheadvantageslistedabove inhighestqualityofworkmanship or in continuing quality control procedures All stainless ste...

Page 3: ...uring equipment the EZ cups may be ordered at an additional charge with a CERTIFICATE of CALIBRATION This document contains not only information on actual cup calibration with standard oils traceable...

Page 4: ...nship beyond the range of the table the mathematical formulas shown on the graphs may be used The first of the formulas shown on the graph is used when efflux SECONDS is known As an example assume 42...

Page 5: ...inserting index finger into handle ring In a quick steady motion lift the cup out of the sample material starting the timer when the top edge of the cup breaks the surface During the flow time hold t...

Page 6: ...en to the right on this line to the 0 6 column The value at the intersection is 111 3 centistokes The tables may be read in reverse to find efflux time in seconds from a known centistoke value CONVERS...

Page 7: ...ted temperature range as shown in the example Within this limited range the plots of the obtained data will normally result in a straight line such as the heavy diagonal line Draw parallel lines as sh...

Page 8: ...owing is taken from ASTM D445 Viscometers used for silicone fluids should be reserved for the exclusive use of such fluids Solvent washings from these viscometers should not be used for cleaning other...

Page 9: ...used in experimental development of these formulas Accessories PU G201 Instruction Manual EZ Series includes Grid Set PU G260 Set 5 Conversion Tables Zahn Signature and EZ Cups VI EZC Seconds Between...

Page 10: ...the standard is prepared expressly for Paul N Gardner Co Inc by the Cannon Instrument Company and that data on the standard is traceable to the National Institute of Standards and Technology A Materi...

Page 11: ...OM THE USE THEREOF OR THAT ANY SUCH USE WILL NOT INFRINGE ANY PATENT This information is furnished upon the condition that the person receiving it shall make his own tests to determine the suitability...

Page 12: ...e the experimentally determined efflux time with the design efflux time If experimental results were at 25 0 C or 77 0 F the comparison should be within the following limits MANUAL TEMPERATURE ADJUSTM...

Page 13: ...e over an extended period of time CAUTION Silicone fluids should not be used to calibrate viscosity cups These materials change the interface between the cup surface and the test material and therefor...

Page 14: ...first process will evaporate quickly after the sample has been flushed from the cup Hypersolve MEK and Alcohol can be used in aluminum cups and Hypersolve and Alcohol for the stainless steel cups Ace...

Page 15: ...the following 1 Gardco Cat No VI 3130 glass mercury filled thermometer 4 1 2 length 20 30 C range 2 Gardco Cat No TH 02232 C ASTM mercury filled glass thermometer 10 8 length 19 27 C range 3 Gardco Ca...

Page 16: ...the temperature remains constant throughout the run 8 Stop the timer when the first definite break in the efflux stream occurs near the bottom of the cup Be sure to keep air bubbles at a minimum they...

Page 17: ...RESULTS TO BE OBTAINED FROM THE USE THEREOF OR THAT ANY SUCH USE WILL NOT INFRINGE ANY PATENT This information is furnished upon the condition that the person receiving it shall make his own tests to...

Page 18: ...cover GARDCO Calibrated Viscosity Cups and are based on conversion formulas of a type with parameters as referenced in The Encyclopedia of Polymer Science Engineering Vol 4 Second Edition John Wiley S...

Page 19: ...e temperature if necessary of the test material Completely immerse the cup into the material to be measured in a location free from bubbles or foam holding the cup vertically by means of the stainless...

Page 20: ...efflux time tolerance Use this formula derived by Paul N Gardner c company research to find viscosity V in centistokes when cup efflux time in seconds T is known Results from the above formulas solved...

Page 21: ...22 7 22 9 23 0 23 1 23 3 23 4 23 5 23 6 23 8 50 23 9 24 0 24 1 24 3 24 4 24 5 24 7 24 8 24 9 25 0 51 25 2 25 3 25 4 25 5 25 7 25 8 25 9 26 0 26 2 26 3 52 26 4 26 5 26 7 26 8 26 9 27 0 27 1 27 3 27 4...

Page 22: ...tistokes when cup efflux time in seconds T is known V 2 80T 747 T Use this formula to find cup efflux time in seconds T when viscosity V in centistokes is known Results from the above formulas solved...

Page 23: ...3 92 7 93 0 40 93 3 93 7 94 0 94 3 94 6 95 0 95 3 95 6 95 9 96 3 41 96 6 96 9 97 2 97 6 97 9 98 2 98 5 98 8 99 2 99 5 42 99 8 100 1 100 5 100 8 101 1 101 4 101 7 102 1 102 4 102 7 43 103 0 103 3 103...

Page 24: ...t 1987 Paul N Gardner Company EZ ZAHN ASTM CUPS CUP 3 CONVERSION FORMULAS AND TABLE EZ viscosity cups are designed to comply with requirements of ASTM D4212 and to take advantage of design changes kno...

Page 25: ...7 359 360 361 362 363 364 365 366 367 38 368 369 370 371 372 373 374 375 376 377 39 378 380 381 382 383 384 385 386 387 388 40 389 390 391 392 393 394 395 396 397 398 41 399 400 401 403 404 405 406 40...

Page 26: ...1987 Paul N Gardner Company EZ ZAHN ASTM DIP CUPS CUP 4 CONVERSION FORMULAS AND TABLE EZ viscosity cups are designed to comply with requirements of ASTM D4212 and to take advantage of design changes k...

Page 27: ...0 412 413 414 406 33 417 419 420 421 423 424 426 427 428 430 34 431 432 434 435 437 438 439 441 442 443 35 445 446 448 449 450 452 453 455 456 457 36 459 460 461 463 464 466 467 468 470 471 37 472 474...

Page 28: ...t 1987 Paul N Gardner Company EZ VISCOSITY CUPS CUP 5 CONVERSION FORMULAS AND TABLE EZ viscosity cups are designed to comply with requirements of ASTM D4212 and to take advantage of design changes kno...

Page 29: ...789 791 794 796 799 801 35 803 806 808 811 813 815 818 820 823 825 36 828 830 832 835 837 840 842 844 847 849 37 852 854 856 859 861 864 866 868 871 873 38 876 878 881 883 885 888 890 893 895 897 39 9...

Page 30: ...e following viscosity cups are calibrated with oils produced in accordance with ISO IEC 17025 GARDCO Standard Ford Cups 0 1 2 3 4 and 5 Cups GARDCO ISO Cups 3mm 4mm 6mm and 8mm Cups GARDCO DIN Cup 4mm...

Page 31: ...ted cup oil combination from twenty 20 to twenty seven 27 degrees Celsius is shown in the above graph The cup may be checked with the indicated G oil with reasonable accuracy within these limits For b...

Page 32: ...0 48 46 44 42 46 70 SECONDS 458 6 CENTISTOKES 20 21 22 23 24 25 26 27 S E C O N D S 70 65 60 55 50 45 40 35 DEGREES CELSIUS 25 DEGREES 25 DEGREES GARDCO EZ VISCOSITY CUPS EFFLUX TIME IN SECONDS TEMPER...

Page 33: ...ISTOKES S E C O N D S 20 21 22 23 24 25 26 27 DEGREES CELSIUS 877 2 CENTISTOKES 38 06 SECONDS 60 55 50 45 40 35 30 25 DEGREES 25 DEGREES GARDCO EZ VISCOSITY CUPS EFFLUX TIME IN SECONDS TEMPERATURE GAR...

Page 34: ...0 22 3 72 1 22 4 72 3 22 5 72 5 22 6 72 7 22 7 72 9 22 8 73 0 22 9 73 2 23 0 73 4 23 1 73 6 23 2 73 8 23 3 73 9 23 4 74 1 23 5 74 3 DEGREES CELSIUS FAHRENHEIT 23 6 74 5 23 7 74 7 23 8 74 8 23 9 75 0 2...

Page 35: ...EACH FL 33060 PHONE 954 946 9454 FAX 954 946 9309 www gardco com email gardner gardco com GARDCO produced viscosity cups are calibrated with standard G Series oils Centistoke viscosity of these oils i...

Page 36: ...27 540 4 4 4 4 4 4 3 3 3 2 2 2 2 3 3 3 3 3 3 5 5 5 5 5 GARDCO MINI FORD DIP CUP 0 GARDCO MINI FORD DIP CUP 1 GARDCO MINI FORD DIP CUP 2 GARDCO MINI FORD DIP CUP 3 GARDCO MINI FORD DIP CUP 4 GARDCO MI...

Page 37: ...S A M P L E S A M P L E 316 N E FIRST ST POMPANO BEACH FL 33060 PHONE 954 946 9454 FAX 954 946 9309 www gardco com email gardner gardco com...

Page 38: ...LS 250 750 MICRONS 0 5 13 15 20 25 380 500 640 1 0 20 MODEL IC 20 60 MILS 500 1500 MICRONS 0 5 13 30 40 50 760 1000 1280 2 0 40 WET FILM THICKNESS GAGE MILS MILS MILS MODEL CC 2 6 MILS 0 2 3 4 5 0 2 M...