![GARANT mLevel User Manual Download Page 23](http://html1.mh-extra.com/html/garant/mlevel/mlevel_user-manual_3436469023.webp)
14. Technical data
14.1. Ambient conditions
The recommendations listed below should be complied with as closely as
possible, since they ensure consistent performance by the device coupled
with the minimum requirement for maintenance.
14.2. Operation
Temperature: +10 °C to +40°
Duty cycle: 10% (S3); 1 min ON, 9 min OFF
Environment: for use only in dry indoor areas
item
max. load*
[kg]
Height adjustment
range
[mm]
92 0001
250
750 – 1000
92 0003
250
750 – 1000
92 0011
250
700 – 1000
92 0013
250
700 – 1000
92 0021
250
700 – 1000
92 0023
250
700 – 1000
*load evenly distributed
Mechanical and electrical data for each lift column.
max. load
max. lifting force
per column 1600 N.
max. lateral load
longitudinally:
1200 Nm static
500 Nm dynamic
transversely:
450 Nm static
255 Nm dynamic
max. lifting speed
9 mm/s at 24 V unloaded.
Drive
Internally mounted DC drive,
integral limit switches and 2
Hall sensors.