7.4.
Returning to saved positions
Press the appropriate M1, M2 or M3 button and keep it depressed until
the desired position has been reached and the drives switch off.
8. Warning and error messages for eLevel /
Warnings and error messages can be shown at the manual switch
display.
These messages are generated by the control system and supply
information about malfunctions and their causes.
Code
Cause
Troubleshooting
E 106
Short circuit at the
manual switch port
The control system has detected a short
circuit at the manual switch port.
Operation of the control system will be
blocked for approx. 10 seconds. Rectify the
fault. After this the control system must be
reinitialised.
E 212
Short circuit at the
Hall sensor
The control system has detected a short
circuit at the Hall sensor or at one or more
drives. Operation of the control system will
be blocked for approx. 10 seconds. Rectify the
fault. After this the control system must be
reinitialised.
F 215
Short circuit at the
motor port
The control system has detected a short
circuit at the power supply or at one or more
drives. Operation of the control system will
be blocked for approx. 10 seconds. Rectify the
fault. After this the control system must be
reinitialised.
F 222
EEPROM read/write
error
System overload! Disconnect the device from
the mains. If the same error message is still
reported after 10 hours, contact your custom-
er service.
F 233
MOSFET defective
A 0
SC reset OK
A 99
Overrun display
A 100
Enforced reset
The control system must be reinitialised.