Code
Cause
Troubleshooting
A 202
Overheating
System overload! Disconnect the device from
the mains. If the same error message is still
reported after 10 hours, contact your
customer service.
A 215
Drive overcurrent
7. Spare parts and accessories
Spare parts:
obtainable from the Hoffmann Group:
www.hoffmann-group.com
8. Technical data
8.1.
Ambient conditions
The recommendations listed below should be complied with as closely as
possible, since they ensure consistent performance by the device coupled
with the minimum requirement for maintenance.
8.2.
Operation
Lifting range:
740 mm – 1140 mm
Temperature:
+10 °C to +40°
Duty cycle:
10% (S3); 1 min ON, 9 min OFF
Environment:
for use only in dry indoor areas
Item
Continuous full load*
[kg]
max. load*
[kg]
92 0051 1500
350
500
92 0055 1500
750
1000
*load evenly distributed
16
DE
EN
FR
IT
ES