FONCTIONNEMENT
SITUATION
LED VERT
LED
ROUGE
OPERATIONS A
EXECUTER
PRÊT À EXÉCUTER LES COMMANDES
ON
OFF
-
ATTENTE EN COURS DE LA FERMETURE
AUTOMATIQUE
LA LED S’ÉTEINT TOUTES
LES 3 SECONDES
OFF
-
MOTEUR EN MONTÉE
CLIGNOTEMENT LENT
AVEC DUTY CYCLE 50%
OFF
-
MOTEUR EN DESCENTE
CLIGNOTEMENT RAPIDE
AVEC DUTY CYCLE 50%
OFF
-
PROGRAMMATION PAUSE
CLIGNOTEMENT BREF
TOUTES LES SECONDE
OFF
VOIR PROCÉDURE 5.1
TEMPS DE TRAVAIL
ON
ON
VOIR PROCÉDURE 5.3
RESET EN COURS
3 CLIGNOTEMENTS TOUTES
LES 3 SECONDES
OFF
PLACER EN OFF
LES DIP 5 ET 6
SIGNAUX D’ANOMALIES
LED ROUGE
OPERATIONS A EXECUTER
1 CLIGNOTEMENT
VÉRIFIER LA CONNEXION CORRECTE DU STOP
2 CLIGNOTEMENTS
VÉRIFIER LE BRANCHEMENT CORRECT DE LA SÉCURITÉ, SÉCURITÉ OCCUPÉE
8 CLIGNOTEMENTS
VÉRIFIER:
• SOURCE DE COURANT
• SURCHARGE SORTIE 12V (BORNES 9-3)
• SURCHARGE SORTIE 24Vac (BORNES 11-12)
ALLUMÉ
DIP MAL POSITIONNE, SUIVRE LA PROCÉDURE SUIVANTE:
1. POSITIONNER TOUS LES DISP SUR OFF
2. ATTENDRE 5 SECONDES
3. POSITIONNER TOUS LES DIPS DANS LA POSITION DÉSIRÉE EN SUIVANT LES IN-
STRUCTIONS
10. ALERTES
Le tableau suivant montre les différents signaux lumineux générés par l’armoire de contrôle avec leur
signification et d’éventuelles opérations à effectuer.