ZR-DH111NP
19
6 FIELD CODE LINE
When the system is connected to the Multiplexer, it is used to adjust the field code line of Multiplexer.
The values: 00~20
The default value is 13, it is suitable for most of the multiplexers.
If the field code line appears on the top of each playback channel, decrease the value.
If multiplexers can not playback properly, increase the value.
7 SYSTEM UPDATE :
YES/NO
Update the system or not.
YES
Copy the update files into Compact Flash card. Insert the Compact Flash card into the slot, and
then press ENTER key to update system.
Notice
After the system is updated successfully, reboot the system.
8 LOAD DEFAULT
YES/NO
Load the System DEFAULT or not.
YES
The confirmation dialog will appear on the screen.
Press ENTER key to NOT load default and Exit.
If not, press RIGHT key to move the cursor to YES, and then press EN-
TER key to load default.
9 CF RENEW
Two of modes for choice, YES or NO.
YES
will format CF card
NO
will not format CF card
10 PLAY MODE
The play mode can be FIELD or FRAME.
: Press LEFT or RIGHT to move the cursor to the left or right.
: Press UP or DOWN or Jog Dial to change the value.
Programming
LOAD DEFAULT
NO
YES
LOAD DEFAULT
NO
YES
UP
LEFT
RIGHT
DOWN
Summary of Contents for ZR-DH111NP
Page 1: ......