background image

6

ZP-EPC10

Product Description

Scope of supply

Protocol converter ZP-EPC10

4 screw clamps

Installation guide

Recommended Accessories

CV12 power supply available from CBC

Cable made to Belden specifications

Summary of features

The ZP-EPC10 protocol converter is designed to convert control signals between
RS422 (full-duplex) and RS485 (half-duplex) protocol. In addition to adjusting for diffe-
rent pin assignments, the unit also converts the protocols used by the CEC C328 video
multiplexer and the SMD-type dome cameras

 

manufactured by

 

CBC. A single protocol

converter can support up to 31 dome cameras. It is also possible to cascade up to nine
protocol converters to control a maximum of 256 dome cameras

 

using a single multi-

plexer.

Both SMD-type and CEC VSD-type dome cameras

 

(only the former use RS485 proto-

col) may be operated jointly.

The following dome camera functions are supported:

Pan, tilt, zoom, focus, iris

Presets

Writing EEPROM

Start position (Home)

Auto-focus, auto-iris, manual iris control

Automatic pan or tilt function between presets 1 and 2

Control of pan and tilt speed

Camera speed control

Note:

Observe the examples and explanations given from page 15 onwards.

Product Description

Summary of Contents for ZP-EPC10

Page 1: ...Installation Guide Protocol converter ZP EPC10 Always read this manual before installing starting up operating storing or otherwise handling any part of the system ...

Page 2: ...This installation guide edition 01 05 2000 is valid for use with the the ZP EPC10 protocol converter year 2000 version ...

Page 3: ...ply 6 Recommended Accessories 6 Summary of features 6 Connections and Switches 7 Installation Connections 8 Configuration 10 Switching on and off 12 Function test 12 Care and maintenance Cleaning 13 Maintenance 13 Passing on Waste Disposal 13 Appendix Conversion table for hexadecimal addresses 14 Typical system configurations 15 Meaning of function keys 18 Troubleshooting 19 Technical data 19 ...

Page 4: ... other application is permitted For further information on operating aspects that are not covered in this guide please contact us at CBC Deutschland GmbH Hansaallee 191 D 40549 Düsseldorf Phone 49 0 211 53 06 70 Fax 49 0 211 53 06 71 80 EU directives The ZP EPC10 protocol converter fulfils the specifications of European Union directive 89 336 covering electromagnetic compatibility Identification p...

Page 5: ...r wet conditions when the item has been pierced after prolonged storage in unfavourable conditions or after difficult transportation Have the device checked by CBC Installation When installing the device electrical engineering regulations should be adhered to Follow the instructions for installation and operation other equipment e g cameras These instructions contain important advice on safety and...

Page 6: ... SMD type dome cameras manufactured by CBC A single protocol converter can support up to 31 dome cameras It is also possible to cascade up to nine protocol converters to control a maximum of 256 dome cameras using a single multi plexer Both SMD type and CEC VSD type dome cameras only the former use RS485 proto col may be operated jointly The following dome camera functions are supported Pan tilt z...

Page 7: ...mal in value 4 OPTIONS switches Reserved for further extensions 5 POWER clamp socket To connect the adaptor 6 DOME clamp socket To link up the control line for the dome cameras 7 TERM switches To terminate the data chain 8 CPU clamp socket For connection of the CEC C328 matrix switcher 9 RCVRS clamp socket For connection of further receivers e g CEC VSD dome cameras or ZP EPC10 converters Connecti...

Page 8: ...r are otherwise suitable and which help to suppress electric interference When laying out the lines and cables make sure that they cannot be easily damaged and ease wherever possible tensile loads and stresses Connections Dome cameras Connect the dome cameras maximum 31 cameras per converter to the converter s DOME contacts Use Belden cables for connections if possible or twisted pair cables based...

Page 9: ...atrix switcher When positioning the converter anywhere in the RS422 chain connect the CPU contacts to the RCVRS contacts of the receiver or converter nearest to the matrix switcher Connect further RS422 receivers e g CEC PTR or CEC VSD or converters with RCVRS contacts of the protocol converter Pin assignment CPU connector 1 Ground 2 Answer Output 3 Answer Output 4 Command Input 5 Command Input Pi...

Page 10: ...ent configuration in the future Normally the TERM 1 switch should be left in the ON position If the protocol converter is the first unit in the dome camera daisy chain DOME connec tion the TERM 2 switch must be in the ON position to terminate the daisy chain correct ly at this end The last dome camera in the daisy chain should also have the terminal resi stor connected In an RS485 cascade if cabli...

Page 11: ... control more than 31 dome cameras it will be necessary to cascade several protocol converter Assuming the first cascaded unit addresses 1 to 31 i e lo wer address 1 the subsequent unit will address cameras starting with 32 and so on If several protocol converters are cascaded together in a single system the lower addresses of consecutive units must differ by at least 31 If necessary the protocol ...

Page 12: ...up the power supply as the last step Note that the protocol converter does not have a power on off switch Simply connect the power supply to the protocol converter and then plug it into the wall mains power socket A red LED will light up on the front panel indicating that the unit is ready for ope ration Function test The CEC C328 video multiplexer has a large number of special features and differ...

Page 13: ...e housing of the protocol converter The device does not contain parts that you can repair or replace yourself Ensure that repair or maintenance work is carried out by qualified personnel electrical engineers Passing on Waste Disposal Always provide these instructions when passing on the protocol converter to another user The device contains agents which can be harmful to the environment Legal requ...

Page 14: ...7 ED 14 0E 46 2E 78 4E 110 6E 142 8E 174 AE 206 CE 238 EE 15 0F 47 2F 79 4F 111 6F 143 8F 175 AF 207 CF 239 EF 16 10 48 30 80 50 112 70 144 90 176 B0 208 D0 240 F0 17 11 49 31 81 51 113 71 145 91 177 B1 209 D1 241 F1 18 12 50 32 82 52 114 72 146 92 178 B2 210 D2 242 F2 19 13 51 33 83 53 115 73 147 93 179 B3 211 D3 243 F3 20 14 52 34 84 54 116 74 148 94 180 B4 212 D4 244 F4 21 15 53 35 85 55 117 75...

Page 15: ...VRS J4 on your CEC C328 Make your selection for the address range between 1 lower address and 12 upper address Assign addresses 1 to 12 to the cameras Use the multiplexer to select any camera in the range 1 to 12 address range 1 12 camera address 1 access through number 1 camera address 12 access through number 12 camera address 2 access through number 2 ...

Page 16: ...the address range on the second converter between 32 and 45 Assign addresses 1 to 31 to the cameras connected to the first converter Assign addresses 1 to 14 to the cameras connected to the second converter Use the multiplexer to select any camera in the range 1 i e camera 1 on the first converter to 45 camera 14 on the second converter address range 1 31 second converter camera address 1 access t...

Page 17: ...es 1 to 3 to the VSD cameras Select the address range on the converter between 4 lower address and 6 upper address Assign addresses 1 to 3 to the SMD cameras Use the multiplexer to select any VSD camera in the range 1 to 3 Use the multiplexer to select any SMD camera in the range 4 to 6 address range 4 6 camera address 1 access through number 4 camera address 3 access through number 6 camera addre...

Page 18: ...OUT zoom out FOCUS NEAR focus near FOCUS FAR focus far IRIS OPEN i e make image brighter IRIS CLOSE i e make image darker PP ENTER save preset and go to preset A P autopan between presets 1 and 2 A I switch auto iris on off L SPD change lense speed faster slower AUX 1 one shot autofocus AUX 2 automatic swing between presets 1 and 2 only vertically AUX 3 change speed of pan for automatic swing fast...

Page 19: ...nterface full duplex 2 5 pin terminal strip RS485 interface half duplex 1 3 pin terminal strip Addressing range 1 256 Operating conditions temperature between 5 40 C relative humidity up to 90 no condensation Dimensions W H L 110 35 165 mm Weight approx 425 g including clamps 0 0 1 2 3 4 2 5 3 2 2 2 4 6 7 8 2 4 0 2 9 2 1 2 2 4 6 7 8 2 4 2 3 2 7 7 6 7 5 3 4 2 7 2 4 0 2 5 0 2 0 2 5 3 2 2 4 0 2 4 0 2...

Page 20: ...3 12 F 44 0 208 202 33 87 CBC Europe Ltd Ufficio Milano Via Carolina Romani 1 11 I 20091 Bresso MI T 39 0 2 66 50 32 10 F 39 0 2 66 50 32 04 CBC Poland Sp z o o Ul G Morcinka 5 Paw 6 PL 01496 Warszawa T 48 0 22 638 4440 F 48 0 22 638 4541 CBC Europe Ltd Paris Branch 1 Avenue des Marguerites ZAC des Petits Carreaux F 94389 Bonneuil sur Marne Cedex T 33 0 1 43 99 04 24 F 33 0 1 43 99 59 06 ...

Reviews: