![Ganz ZN-PT304L User Manual Download Page 53](http://html.mh-extra.com/html/ganz/zn-pt304l/zn-pt304l_user-manual_561080053.webp)
-
52
-
0
Do not turn off the led indicator
ledoff
(r/w)
1
Turn off the led indicator
<yyyy/mm/dd>
year, month and date separated by slash.
<keep> keep
date
unchanged
date
(r/w)
<auto>
Using NTP to sync date/time automatically
<hh:mm:ss>
hour, minute and second separated by colon.
<keep> keep
date
unchanged
time
(r/w)
<auto>
Using NTP to sync date/time automatically
ntp
(r/w)
<domain name or IP
address>
NTP server
<skip to invoke default server>
timezone
(r/w)
-12 ~ 12
time zone, 8 means GMT +8:00
<8>
updateinterval
(r/w)
0 ~ 2592000
0 to Disable automatic time adjustment,
otherwise, it means the seconds between
NTP automatic update interval.
<0>
serialnumber
(r)
<mac address>
12 characters mac address without hyphen
connected
firmwareversion
(r)
<text string shorter
than 39 characters>
The version of firmware, including model,
company, and version number
0
Restore the system parameters to default
value.
restore
(w)
Positive integer
Restore the system parameters to default
value and restart the server after <value>
seconds.
0 ~ 65535
Restart the server after <value> seconds.
reset
(w)
-1
Not restart the server.
Viewmode (r/w)
0
Using the profile of viewing by computer
Group: Security
NAME VALUE DESCRIPTION
username_<1~20
>
<text string shorter
than 16 characters>
change user name.
<blank>