BLC
OFF
Flange back adjustment wheel
If focus needs to be adjusted after the lens has been mounted, loosen the Flange back lock screw (
)
and rotate the Adjustment wheel to adjust.
DC iris level adjust POT
Adjust DC iris level manually.
D D/N (digital day/night) select switch
The camera image digital processing produces well-lit images even in low illumination environments.
While this function is operating, the image will be monochrome: When the environment in which the
camera is installed becomes brighter, color image will automatically result.
ON:
Day/Night automatic switching (low illumination: monochrome; normal lighting: color)
OFF:
Fixed to color image
Easy Focus adjustment
Be sure to adjust the lens focus only in a well-lit environment. When using a DC iris lens, set the auto-iris
mode switch (
) to AES, and then make the focus adjustment. After the adjustment, be sure to return
switch (
) to DC.
FLC switch
ON:
Shutter speed to be fixed at 1/100 sec.
OFF:
Normal position (Fixed at 1/60 second)
BLC (Back Light Compensation) mode switch
When strong light (sun, sky, illumination, etc.) is present behind the object being
photographed, the object will appear dark. In this case, put this switch in the
position.
Sync mode switch
For setting the sync mode.
L.L.:
Line Lock mode
INT.:
Internal sync mode
Line phase adjustment POT
This POT is used to adjust phase when the Sync mode switch is set to
position.
Auto-iris output connector
For connecting the cable of an auto-iris lens. The pin assignment is following.
No.
DC
VIDEO
1
CONTROL –
DC 12 V (max. 50 mA)
2
C
N. C.
3
DRIVE +
VIDEO
4
DRIVE –
GND
Flange back lock screw
Auto-Iris mode switch
For switching the output from the auto-iris connector (
).
DC:
To be set when using a non-amp auto-iris lens.
AES:
To be set when using fix iris lens.
VIDEO: To be set when using an auto-iris lens a built-in amp.
Video output connector
Connected to the TV monitor with a coaxial cable.
Power input terminal
Use a DC 12V (10.8 to 13.2 V) or AC 24 V (21.6 to 26.4 V, 59 to 61 Hz) power supply.
Caution: Use only with a 24V AC power supply marked class 2 or +12VDC power supply
Description of Functions
US
YC04_YCH04_FC64_FCH64.indd 11
2008/10/30 18:31:36