background image

5

www.gantner.com

Valid as from September 27

th

 2013 • Technical data subject to modifications without notice! 

DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734

Mounting procedure

Note:  Before mounting all locks of the locker system a test installation of 

at least one lock and final function check must be performed like 
described below. Only if the tests are successful the rest of the 
locks may be mounted in the same way.

1.  Drill the 3 holes (3) for the GAT NET.Lock 7000 into the locker wall. 
2.  Plug-in the connection cable (see page 6).
3.  Mount the GAT NET.Lock 7000 with 3 screws (3) on the inside locker 

wall.

 

Note: Use the right screws according to the type of locker material.

Attention:

  The  max.  allowed  tightening  torque  of  the  screws 

is 2 Nm.

4.  On the inner wall of the locker door make the cut-out (62.6 x 68 mm) 

for the GAT NET.Lock Bolt Set 7200.

5.  On the inner wall of the locker door drill the 4 holes (6) for mounting 

the GAT NET.Lock Bolt Set 7200.

6.  On the outer wall of the locker door make the cut-out (67.6 x 93.5 mm) 

for the label carrier.

7.  Mount the bolt set onto the inside wall of the locker door by using 4 

screws as shown in the figure on the previous page.

 

Note:

 Only use Torx pan-head metal screws, Ø 3.5 mm, length 9.5 mm.

Attention:

  The  max.  allowed  tightening  torque  of  the  screws 

is 2 Nm.

8.  Push the label carrier onto the outside wall of the locker door. The 

label carrier will hold in place with the lashes on the label carrier. No 

screws are required.

9.  Stick the front label (11) onto the label carrier.

Note:  A customer-specific front label can be used to cover the LED 

hole. A transparent field should be placed on the label to show 
the LED light.

10. Close the door to test, if the locker door can be closed easily and if the 

door shackle inserts into the opening of the GAT NET.Lock 7000.

3

3

3

3

2

2

6

7

1

6

9

6

6

10

7

123

11

7

3

3

4

5

1

Loc

ker wall

50.0 mm

6.0 mm

94.0 mm

 1.0 mm

Loc

ker door (outside wall)

Loc

ker door (inside wall)

Loc

ker wall

74.0 mm

17.0 mm

17.0 - 17.5 mm

min. 18 mm

max. 26 mm

Inside of Locker

Locker Door

(Front view without lable carrier)

Locker Door

(Front view with lable carrier)

15.1 mm

32.6 mm

6

0.1 mm

Middle of the opening

for the door shakle

Loc

ker wall

Locker Door

(Front view with lable carrier)

Reviews: