Standalone Digital MMC Control
92
MMC Hardware Manual
G & L Motion Control Inc.
control. I/O can be added using G&L Motion Control’s serially distributed
Block I/O.
Additionally, a maximum of four field-installable Option Modules can be
added directly to the Control, as follows:
•
Up to two MMC Communications Option Modules (Profibus or
DeviceNet).
•
Up to four MMC 32 In/32 Out Option Modules.
5.4
Power Supply Requirements
The Standalone Digital MMC Control is powered by user-supplied 24 Vdc
(nominal). The maximum power consumption is 1A (24 W). Also, MMC
Option Modules attached to the Standalone Digital MMC Control draw
power from the Control’s 24 Vdc connector. When determining the size of
the 24 Vdc power supply, use the worksheet found in
Table 5-1:
Power Supply Worksheet
MMC Module
Current
(mA)
# of
Units
Col A
Subtotal
(mA)
Col B
Current
(mA)
64 Axis Standalone Digital MMC
Control (-D64)
1,000
32 Axis Standalone Digital MMC
Control (-D32)
900
Axis I/O Option Module
100
MMC Ethernet Option Module
200
MMC DeviceNet Option Module
100
MMC Profibus Option Module
100
MMC 32 In/32 Out Option
Module
100
Required power supply current (Add Column A)
Summary of Contents for MMC-A2
Page 1: ...Standalone MMC TM Hardware Manual Version 15 0 G L Motion Control Inc...
Page 2: ......
Page 36: ...Installation Operation Maintenance 28 MMC Hardware Manual G L Motion Control Inc...
Page 124: ...Standalone Digital MMC Control 116 MMC Hardware Manual G L Motion Control Inc...
Page 136: ...MMC Ethernet TCP IP Option Module 128 MMC Hardware Manual G L Motion Control Inc...
Page 175: ...CE and EMC Guidelines G L Motion Control Inc MMC Hardware Manual 167...
Page 176: ...CE and EMC Guidelines 168 MMC Hardware Manual G L Motion Control Inc...
Page 177: ...CE and EMC Guidelines G L Motion Control Inc MMC Hardware Manual 169...
Page 178: ...CE and EMC Guidelines 170 MMC Hardware Manual G L Motion Control Inc...
Page 186: ...Appendix A Operation Details 178 MMC Hardware Manual G L Motion Control Inc...