G&G TJ3K Operating Instructions Manual Download Page 5

displays the total weight and the number-of-pieces field the total weight.

H

Meaning the preset quantity is exceeded and an audible warning is given.

5.3The quantity field displays the following information:

F---1

The value of the number-of-pieces exceeds the range of display

5.4 Indicators

kg

g

Lights when the data are stable. The current weight unit is in kg

g

lb

Lights when the data are stable. The current weight unit is in lb.

SAMP↑

Lights when the total sampling amount is less than the min. sampling value.
Now, add the number of samples till the indicator is out. Set by re-sampling to
ensure the accuracy.

UNIT↑

Lights when the average or set unit weight is less than the min. unit weight
value. Now, the counting weighing apparatus remains serviceable but error may
happen during the counting. It is recommended that counting weighing
apparatus with high distinguishability is used.

Under-voltage

Lights when the voltage of the battery is insufficient along with audible alarm,
charge the battery. Otherwise, the battery operates only 1-2 hours. The counting
weighing apparatus operates normally during the charge.

Charging

Lights when the counting weighing apparatus is in the charging state. It takes
about 8 hours for one charge.

Fully charged

Slowly lights when the counting weighing apparatus is under charge. When the
charging lamp dies out, it indicates that it is fully charged. Now, it allows further
charging.

6

Setting of adjustable parameters

Start the unit by holding down the “QTY PST” key till it comes to “F----3” and you are in the
setting mode. Press the “QTY PST” key to change the parameters to be set and press the
“TARE” key to change the parameter value.

C1---- for setting the sensitivity at 0 1 2 3 4. The higher the value and the poorer the
sensitivity, the better the stability is. The factory setting is 2.

C2---- for setting the filtering intensity at 0 1 2 3. The higher the value and the slower the
response speed, the better the stability is. The factory setting is 1 or 0.

C3---- for setting the baud rate at 2(600) 3(1200) 4(2400) 5(4800) 6(9600). The factory
setting is 6.

C4---- for setting the communication number. The “TARE” key changes the low-value and
the “kg/lb” key changes the high-value. The data are the first data to be received during the
communication. The factory setting is 27.

Start the unit by pressing the “TARE” key and all set parameters and calibrated data return
the factory state. Before service, perform re-calibration.

Summary of Contents for TJ3K

Page 1: ...arm and more 1 5 Use of green LED display allowing distinct display and visible readings 1 6 The electronic counting weighing apparatus allows options of data output interface and printing button dire...

Page 2: ...he display window displays the negative value of the weight of the container Nevertheless press the TARE key and the Packaging Removal function is canceled and zero is displayed for the weight 3 3 Cal...

Page 3: ...perations and the quantity display window displaying the total weight After about 5s you are again in the counting state where the weight display window displays the current weight the unit weight win...

Page 4: ...ed weight value and value for number of pieces are re established after the unit weight window displays the accumulated number of operations for 5s and the next accumulation is possible only when the...

Page 5: ...Charging Lights when the counting weighing apparatus is in the charging state It takes about 8 hours for one charge Fully charged Slowly lights when the counting weighing apparatus is under charge Wh...

Page 6: ...display accumulation MW 12345 6 kg 15 bits MN 12 12 bits MQ 12345 Pcs 14 bits 7 3 Receive order need to receive the communication then receive order When the communication setting is 27 default statue...

Page 7: ...he producer offers a free repair service to all G G Product which become defect under proper usage without human damage The customers are kindly requested to mail the product as well as its original p...

Page 8: ...ical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances w...