Default setting is 6 .

C4---- Communication setting. “TARE” changes the lower unit.

“M+” changes the high unit. This date is the first date during

communication. Default setting is 27.

Holding down the “TARE” and power on , all the parameters can be

reset to default settings, re-calibration before using.

8. Serial communication

8.1 Serial communication protocol: baud rate: 600-9600 can set, the

default settings is 9600; data units: 8 units; ending unit: 1 unit; no

calibration unit.

8.2 Data format: 41-bit data output

ASCII code

WT

space

negative

data

unit

enter

2 unit

1 unit

1 unit

7 unit

3 unit

1 unit

UW

space

data

unit

enter

2 unit

1 unit

6 unit

2 unit

1 unit

QT

space

data

unit

enter

linefeed

2 unit

1 unit

5 unit

4 unit

1 unit

1 unit

When data is not negative, the negative unit is space, no showing

data is also space.

For example: weight showing 12.345 kg, unit weight showing 12.34,

Summary of Contents for TJ15KY-0.5

Page 1: ...series of electronic scale TJ3KY 0 1 TJ6KY 0 1 TJ15KY 0 5 TJ30KY 1 In order to better use of your electronic balance and keep it good working condition Please read the manual carefully and properly p...

Page 2: ...ions and Performance indexes 4 3 Shape and Installation of scale 5 4 Precaution before using The Scale 5 5 Operational method 7 6 Display Information 12 7 Setting and meaning 14 8 Serial Communication...

Page 3: ...ed line mode excellent selection and manufacturing process thus products with high reliability anti interference capability and full lifetime Good stability for full lifetime using also can be used to...

Page 4: ...3K 0 1 Capacity 30kg 15kg 6kg 3kg Resolution 1g 0 5g 0 1g 0 1g Calibration Graduation 10d 10d 10d 10d Tare Scope 30kg 15kg 6kg 3kg Calibrating Weight 20kg 10kg 5kg 2kg Min sampling value 20g 10g 2g 2g...

Page 5: ...232 data output 11 Power socket 4 Precaution before using the Scale 4 1 Using environment indoor max Altitude 2000m temperature 0 40 Humidity 80 fluctuations less than 10 The scale should be avoided g...

Page 6: ...ltage is low the LOW POWER indicator will be shown Please turn the scale off and then fully recharge it otherwise the scale will automatically turn off to protect there chargeable battery 4 7 Because...

Page 7: ...indows displays OFF the scale will turn off automatically 5 1 2 Tare 5 1 2 1 With empty scale platform the displaying deviates from zero pressing TARE key then the displaying will return to zero 5 1 2...

Page 8: ...or the weight 5 1 3 Quantity setting In the numbers input status press the SMPL key to set the current input as number When the unit weight of the article to be weighed is unknown place the article to...

Page 9: ...1 5 Unit conversion Press kg lb key and the displayed value for weight display window switches between kg kilogram and lb pound and the indicator for relevant unit lights The unit conversion in the w...

Page 10: ...w press the M key and the weight display window displays the total weight with the unit weight window displaying the accumulated number of operations and the quantity display window displaying the tot...

Page 11: ...g state it clears the entered numbers When it is not in the number entering state it clears number of pieces 5 2 Calibration method If the scale has not been used for a long time or just newly bought...

Page 12: ...battery is near empty one single charge more than 10 hours and battery symbol dynamic display after filled the battery symbol is not indicated at the same time it can continue charge Scale can work no...

Page 13: ...ry symbol Instructions of battery when using battery fully charged battery shows full grid When the battery runs low display spaces and a warning sound this time should be charged if not it only work...

Page 14: ...lution is used 6 3 The quantity field displays the following information F 1 The value of the number of pieces exceeds the range of display 7 Setting of adjustable parameters Holding down the kg lb th...

Page 15: ...ion protocol baud rate 600 9600 can set the default settings is 9600 data units 8 units ending unit 1 unit no calibration unit 8 2 Data format 41 bit data output ASCII code WT space negative data unit...

Page 16: ...the communication setting is 27 default statue in other words Hexadecimal system 1BH the orders to scale are 1BH 70H ACS code p print scale required to send date once 1BH 71H ACS code q calibration 1...

Page 17: ...ettings 9600 n 8 1 MSComm1 Output Chr H1B Chr H70 send a print order or MSComm1 Output Chr 27 Chr 112 or MSComm1 Output Chr 27 p Do DoEvents Loop Unti MSComm1 InBufferCount 41 a MSComm1 Input Print a...

Page 18: ...ase send the balance together with the original product packing to factory for free repair Our factory responsible for the receipt of the date of repaired and sent within one week or be replaced 10 3...

Page 19: ...es need repair can send the following address G G MEASUREMENT PLANT service group ADD xushi town changshu jiangsu TEL 0512 52671954 FAX 0512 52671339 Zip code 215535 The company must provide the detai...