7. Cautions for operation

 

7.1 For best performance, the balance should be put on an stable desk, where there 

is no vibration. 

 
7.2  Using  environment:  indoor,  max.  Altitude:  2000m,  temperature:  0-40

humidity ≤80%, Power fluctuations less than ±10% 

 
7.3 The electronic scale is a precision instrument which needs to be gently handled 

during  the  weighing  of  articles.  Avoid  impact  and  heavy  load  on  top  (never 
exceed  its  max.  weighing  limit).  Any  forms  of  impact  or  overloading  many 
cause permanent damage to the electronic balance, even in the use of electronic 
balance without power supply.   

 
7.4.  Please  use  separate  and  individual  plug  for  the  balance  to  avoid  any  possible 

interference or disturbance.   

 
7.5 Place the scale on a firm  table for operation, and make sure that the operating 

environment of the balance is free of great vibration and interference of power 
supply, and of corrosive gases and liquids.   

 
7.6 Ensure the warm-up time after power-on. 
 
7.7 Remove the object on the pan by turning on the balance 
 
7.9 Avoid any water contact with the balance 

 
      7.10 Warning: If the equipment is used in a manner not specified by this instruction 

the perfection provided by the equipment may be impaired 

 
      7.11 Gentle handling in daily using, with dry and clean cotton cloth cleaning.

 

 

Summary of Contents for TC50K

Page 1: ...1 41564 Kaarst Germany Operation Manual For Models TC50K TC60K TC100K TC150K TC200K TC300K TC60KA TC75KA TC100KA TC150KA TC300KA To guarantee the best performance of the device please read this operat...

Page 2: ...Specification and technical data 3 Operation method 4 Attachment Configuration and description of function Change 5 Data transmission 6 Structure 7 Caution for Operation 8 Trouble shooting 9 Packing...

Page 3: ...apting to the adverse environment and long hours continuous work With double power supply AC DC With auto calibration With Count function the counting of Object with large quantity simplified Unit con...

Page 4: ...kg 0 150 kg 0 200 kg 0 300 kg Plattform Dimension 520 x 410 mm Volume 970 B x 515 T x 205 H mm Power Supply AC 230V 50Hz 60Hz 4W Rechargeable Battery DC 6V 4Ah 20HR Use Temperature 0 40 Use Humidity 8...

Page 5: ...till press TARE to return to zero 3 3 The units can be changed between kg and lb Press to change the units during weighting 3 4 To use the balance in dark place press the key to active the background...

Page 6: ...to change the configuration and function the display shows C1 and the relevant number which can be changed Pressing can change the parameters pressing TARE can change the values of parameters 4 1 C1 s...

Page 7: ...enter 2unit 7units 3unit 1 unit 1 unit 3 8 4 Check bits no check bits 3 8 5 Output pins content 9 core socket 2 pins RXD 3 pins TXD 5pins GND 3 8 6 Computer can control balance though RS232 The order...

Page 8: ...8 P a g e 6 Structure 1 TARE key 2 Background light key 3 COUNT key 4 Kg lb key for unit change 5 PRINT key 6 ON OFF key 7 Special signal interface 8 RS 232 interface 9 Power supply...

Page 9: ...use of electronic balance without power supply 7 4 Please use separate and individual plug for the balance to avoid any possible interference or disturbance 7 5 Place the scale on a firm table for op...

Page 10: ...e message F H 1 Object weight beyond capacity 3 Error by sensor 1 remove the object 2 restore the fabric configuration The message C L by Calibration Error by sensor restore the fabric configuration T...

Page 11: ...ing the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health...